Patient-Specific Modeling of Cardiovascular Mechanics
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Advances in numerical methods and three-dimensional imaging techniques have enabled the quantification of cardiovascular mechanics in subject-specific anatomic and physiologic models. Patient-specific models are being used to guide cell culture and animal experiments and test hypotheses related to the role of biomechanical factors in vascular diseases. Furthermore, biomechanical models based on noninvasive medical imaging could provide invaluable data on the in vivo service environment where cardiovascular devices are employed and on the effect of the devices on physiologic function. Finally, patient-specific modeling has enabled an entirely new application of cardiovascular mechanics, namely predicting outcomes of alternate therapeutic interventions for individual patients. We review methods to create anatomic and physiologic models, obtain properties, assign boundary conditions, and solve the equations governing blood flow and vessel wall dynamics. Applications of patient-specific models of cardiovascular mechanics are presented, followed by a discussion of the challenges and opportunities that lie ahead.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Peskin, C. S. (2002) · Acta Numerica · doi:10.1017/s0962492902000077 · Cited by 4,603 · cited 4×
“Peskin CS. 1972.”
MethodInfluentialCompensatory Enlargement of Human Atherosclerotic Coronary Arteries
Glagov, S., Weisenberg, E., Zarins, C. K., Stankunavicius, R., & Kolettis, G. J. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162204 · Cited by 3,623
Level Set Methods and Fast Marching Methods
Sethian, J. A. (1999) · Medical Entomology and Zoology · Cited by 3,616
Flow patterns around heart valves: A numerical method
Peskin, C. S. (1972) · Journal of Computational Physics · doi:10.1016/0021-9991(72)90065-4 · Cited by 3,047
Verification and Validation in Computational Science and Engineering
Roache, P. J. (1998) · Cited by 2,157
Deformable models in medical image analysis: a survey
McInerney, T., & Terzopoulos, D. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(96)80007-7 · Cited by 1,913
A geometric model for active contours in image processing
Caselles, V., Catt�, F., Coll, T., & Dibos, F. (1993) · Numerische Mathematik · doi:10.1007/bf01385685 · Cited by 1,743
Lagrangian-Eulerian finite element formulation for incompressible viscous flows
Hughes, T. J. R., Liu, W. K., & Zimmermann, T. K. (1981) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(81)90049-9 · Cited by 1,524
Cited by
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Self-citationPatient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
Self-citationComputational fluid dynamics modelling in cardiovascular medicine
Morris, P. D., Narracott, A., von Tengg-Kobligk, H., Silva Soto, D. A., Hsiao, S., Lungu, A., Evans, P., Bressloff, N. W., Lawford, P. V., Hose, D. R., et al. (2016) · Heart · doi:10.1136/heartjnl-2015-308044 · Cited by 495
A review of predictive nonlinear theories for multiscale modeling of heterogeneous materials
Matouš, K., Geers, M. G. D., Kouznetsova, V. G., & Gillman, A. (2017) · Journal of Computational Physics · doi:10.1016/j.jcp.2016.10.070 · Cited by 493
Computational models in cardiology
Niederer, S. A., Lumens, J., & Trayanova, N. A. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0104-y · Cited by 434
Pulse Wave Propagation in the Arterial Tree
van de Vosse, F. N., & Stergiopulos, N. (2011) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122109-160730 · Cited by 387
Multiscale Modeling Meets Machine Learning: What Can We Learn?
Peng, G. C. Y., Alber, M., Buganza Tepole, A., Cannon, W. R., De, S., Dura-Bernal, S., Garikipati, K., Karniadakis, G., Lytton, W. W., Perdikaris, P., et al. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-020-09405-5 · Cited by 353
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Tesche, C., De Cecco, C. N., Baumann, S., Renker, M., McLaurin, T. W., Duguay, T. M., Bayer, R. R., Steinberg, D. H., Grant, K. L., Canstein, C., et al. (2018) · Radiology · doi:10.1148/radiol.2018171291 · Cited by 244
External tissue support and fluid–structure simulation in blood flows
Moireau, P., Xiao, N., Astorino, M., Figueroa, C. A., Chapelle, D., Taylor, C. A., & Gerbeau, J.-F. (2012) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0289-z · Cited by 244
“Unlike other medical imaging modalities such as Doppler ultrasound and phase-contrast magnetic resonance imaging (PCMRI) that enable non-invasive measurement of blood flow (Taylor and Figueroa 2009), CT data do not provide velocity information.”
BackgroundSelf-citationThe cardiovascular system: Mathematical modelling, numerical algorithms and clinical applications
Quarteroni, A., Manzoni, A., & Vergara, C. (2017) · Acta Numerica · doi:10.1017/s0962492917000046 · Cited by 232
“Here, among the several books, monographs and review papers published so far, we mention Formaggia, Quarteroni and Veneziani (2009a), Taylor and Figueroa (2009) and Quarteroni, Veneziani and Vergara (2016c) for the circulatory system, and Peskin (2002), Smith, Nickerson, Crampin and Hunter (2004),…”
BackgroundImage-based large-eddy simulation in a realistic left heart
Chnafa, C., Mendez, S., & Nicoud, F. (2014) · Computers & Fluids · doi:10.1016/j.compfluid.2014.01.030 · Cited by 193
“However, for high stress levels and in large vessels, non-Newtonian effects are usually neglected and blood is usually modelled as an incompressible Newtonian fluid in numerical simulations [24,39].”
BackgroundA modular numerical method for implicit 0D/3D coupling in cardiovascular finite element simulations
Esmaily Moghadam, M., Vignon-Clementel, I. E., Figliola, R., & Marsden, A. L. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.07.035 · Cited by 190
Patient-Specific Cardiovascular Computational Modeling: Diversity of Personalization and Challenges
Gray, R. A., & Pathmanathan, P. (2018) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-018-9792-2 · Cited by 160
“Our review is meant to build upon previously published excellent reviews of cardiovascular modeling including whole heart electrophysiology [14] and electromechanics [15, 16], as well as fluid dynamics [17 – 20].”
MethodA practical approach to parameter estimation applied to model predicting heart rate regulation
Olufsen, M. S., & Ottesen, J. T. (2013) · Journal of Mathematical Biology · doi:10.1007/s00285-012-0535-8 · Cited by 106
Metadata
- Authors
- Taylor, C. A., & Figueroa, C. A.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 109-134
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2117179898
- Cited by
- 451
- References
- 88
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.