The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Targeted Drug-Aerosol Delivery in the Human Respiratory System
Abstract
Inhalation of drug aerosols is a modern pathway to combat lung diseases. It is also becoming the preferred route for insulin delivery, pain management, cancer therapy, and nanotherapeutics. Popular delivery devices include nebulizers, metered-dose inhalers, and dry-powder inhalers. They are all nondirectional and hence have typically low particle deposition efficiencies in desired nasal or lung areas. Thus, for specific disease treatment with costly and/or aggressive medicine, it is necessary to provide targeted drug–aerosol delivery to predetermined sites in the human respiratory system. Experimental measurements and computer models of particle transport and deposition in nasal and lung airway models are presented. Furthermore, the underlying methodology and performance of pressurized metered dose inhalers as well as new smart inhaler systems are discussed. To maximize respiratory drug delivery to specific sites, an optimal combination of particle characteristics, inhalation waveform, particle release position, and drug-aerosol dosage has to be achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heyder, J. (2004) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200409-046ta · Cited by 601
Sakagami, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.012 · Cited by 331
Cited by
Adaptation of Pseudomonas aeruginosa to the cystic fibrosis airway: an evolutionary perspective
Folkesson, A., Jelsbak, L., Yang, L., Johansen, H. K., Ciofu, O., Høiby, N., & Molin, S. (2012) · Nature Reviews Microbiology · doi:10.1038/nrmicro2907 · Cited by 715
Influence of particle size on regional lung deposition – What evidence is there?
Carvalho, T. C., Peters, J. I., & Williams III, R. O. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.12.040 · Cited by 614
Mangal, S., Gao, W., Li, T., & Zhou, Q. (2017) · Acta Pharmacologica Sinica · doi:10.1038/aps.2017.34 · Cited by 288
Ruge, C. A., Kirch, J., & Lehr, C.-M. (2013) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(13)70072-9 · Cited by 280
Topical drug delivery systems: a patent review
Singh Malik, D., Mital, N., & Kaur, G. (2016) · Expert Opinion on Therapeutic Patents · doi:10.1517/13543776.2016.1131267 · Cited by 192
Metadata
- Authors
- Kleinstreuer, C., Zhang, Z., & Donohue, J. F.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2008-08-01
- Volume
- 10
- Issue
- 1
- Pages
- 195-220
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2140718395
- Cited by
- 267
- References
- 2
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Targeted Drug-Aerosol Delivery in the Human Respiratory System. https://app.cochat.ai/papers/10.1146/annurev.bioeng.10.061807.160544
- The paper
- Kleinstreuer, C., Zhang, Z., & Donohue, J. F. (2008). Targeted Drug-Aerosol Delivery in the Human Respiratory System. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev.bioeng.10.061807.160544
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.