I NDOOR A IR Q UALITY F ACTORS IN D ESIGNING A H EALTHY B UILDING
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
▪ Abstract Current guidelines for green buildings are cursory and inadequate for specifying materials and designing ventilation systems to ensure a healthful indoor environment, i.e. a “healthy building,” by design. Public perception, cultural preferences, litigation trends, current codes and regulations, and rapid introduction of new building materials and commercial products, as well as the prevailing design-build practices, pose challenges to systems integration in the design, construction and operation phases of modern buildings. We are on the verge of a paradigm shift in ventilation design thinking. In the past, thermal properties of air within a zone determined heating, ventilating, and air-conditioning specifications. In the future, occupant-specific and highly responsive systems will become the norm. Natural ventilation, displacement ventilation, and microzoning with subfloor plenums, along with the use of point-of-source heat control and point-of-use sensors, will evolve to create a “smart,” responsive ventilation-building dynamic system. Advanced ventilation design tools such as the modeling of computational fluid dynamics (CFD) will be used routinely. CFD will be integrated into air quality and risk assessment models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The numerical computation of turbulent flows
Launder, B. E., & Spalding, D. B. (1974) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(74)90029-2 · Cited by 12,833
Development of turbulence models for shear flows by a double expansion technique
Yakhot, V., Orszag, S. A., Thangam, S., Gatski, T. B., & Speziale, C. G. (1992) · Physics of Fluids A: Fluid Dynamics · doi:10.1063/1.858424 · Cited by 2,832 · cited 1×
“Recently, the RNG k-ε model (74) is the most widely used.”
BackgroundA numerical study of three-dimensional turbulent channel flow at large Reynolds numbers
Deardorff, J. W. (1970) · Journal of Fluid Mechanics · doi:10.1017/s0022112070000691 · Cited by 1,982 · cited 1×
“Large-Eddy Simulation (LES) was developed in the early 1970s by Deardorff (72) for meteorological applications.”
BackgroundClimate considerations in building and urban design
Givoni, B. (1997) · Medical Entomology and Zoology · Cited by 896
COMPARISON OF DIFFERENTk-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS
Chen, Q. (1995) · Numerical Heat Transfer Part B Fundamentals · doi:10.1080/10407799508928838 · Cited by 779
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Self-citationConcentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557 · cited 2×
“Fisk (66) found that, with a doubling of minimum ventilation rates, building energy use would increase modestly (e.”
BackgroundEstimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549 · cited 2×
“Performance-based concepts for ventilation standards that acknowledge the primacy of healthy indoor air will prevail in the 21st century, especially as linkages between healthy building design and business profitability become increasingly apparent (15, 16, 17, 18).”
BackgroundWargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
The use of moments for assessing air quality in ventilated rooms
Sandberg, M., & Sjöberg, M. (1983) · Building and Environment · doi:10.1016/0360-1323(83)90026-4 · Cited by 331 · cited 1×
“The most original definition was from Sandberg & Sjoberg (71).”
BackgroundRisk in cleaning: chemical and physical exposure
Wolkoff, P., Schneider, T., Kildesø, J., Degerth, R., Jaroszewski, M., & Schunk, H. (1998) · Science of The Total Environment · doi:10.1016/s0048-9697(98)00110-7 · Cited by 287 · cited 8×
“Little et al (38) simulated the VOC emissions from new carpets using the assumption that the VOCs originate predominately in a uniform slab of polymer backing material.”
BackgroundInfluentialNon-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284 · cited 1×
“Mendell reviewed these and other studies in an attempt to identify common identifying factors (20).”
BackgroundBusch, J. F. (1992) · Energy and Buildings · doi:10.1016/0378-7788(92)90016-a · Cited by 263 · cited 1×
“Busch (60) conducted thermal comfort surveys in Bangkok offices.”
BackgroundPotential reactions among indoor pollutants
Weschler, C. J., & Shields, H. C. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00219-7 · Cited by 257 · cited 1×
“Suspected is acquired sensitization to the various ingredients and the reaction products formed when citric based solvents react with the ozone (34, 35, 36).”
BackgroundIndoor chemistry: ozone, volatile organic compounds, and carpets
Weschler, C. J., Hodgson, A. T., & Wooley, J. D. (1992) · Environmental Science & Technology · doi:10.1021/es00036a006 · Cited by 233 · cited 1×
“Suspected is acquired sensitization to the various ingredients and the reaction products formed when citric based solvents react with the ozone (34, 35, 36).”
BackgroundBuilding-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720140028029 · Cited by 158 · cited 1×
“Tools for Designing Ventilation Increased awareness of the potential health risks associated with indoor air pollutants (68, 69, 70) has stimulated interest in improving our understanding of how ventilation air is distributed and how pollutants are transported in buildings.”
BackgroundIndoor Allergens—Assessing and Controlling Adverse Health Effects
Pope, A. M. (1993) · JAMA · doi:10.1001/jama.1993.03500210021010 · Cited by 138
Cost avoidance and productivity in owning and operating buildings.
Woods, J. E. (1989) · PubMed · Cited by 124
Nasal pungency and odor of homologous aldehydes and carboxylic acids
Cometto‐Muñiz, J. E., Cain, W. S., & Abraham, M. H. (1998) · Experimental Brain Research · doi:10.1007/s002210050270 · Cited by 123 · cited 2×
“Cometto-Muniz & Cain (44) and Cometto-Muniz et al (45) show that, within families of organic compounds (i.e., acetates, ketones, alkylbenzenes, aldehydes), more carbon atoms usually translates to an increased odor and irritation potential.”
BackgroundFormation of strong airway irritants in a model mixture of (+)-α-pinene/ozone
Wolkoff, P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(98)00292-1 · Cited by 102 · cited 1×
“Suspected is acquired sensitization to the various ingredients and the reaction products formed when citric based solvents react with the ozone (34, 35, 36).”
BackgroundA macroscopic taxi model for passenger demand, taxi utilization and level of services
Yang, H., Lau, Y. W., Wong, S. C., & Lo, H. K. (2000) · Transportation · doi:10.1023/a:1005289504549 · Cited by 100
Assessment of Pollutant Emissions from Dry-Process Photocopiers
Brown, S. K. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00005.x · Cited by 85
Organic Emissions from Consumer Products and Building Materials to the Indoor Environment
Tichenor, B. A., & Mason, M. A. (1988) · JAPCA · doi:10.1080/08940630.1988.10466376 · Cited by 79
Evaluating Sources of Indoor Air Pollution
Tichenor, B. A., Sparks, L. E., White, J. B., & Jackson, M. D. (1990) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1990.10466703 · Cited by 72
PART III. ASSESSING IRRITATION: Sensory Irritation: Relation to Indoor Air Pollutiona
Cometto‐Muñiz, J. E., & Cain, W. S. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb16539.x · Cited by 68
Respiratory irritation due to carpet shampoo: Two outbreaks
Kreiss, K., Gonzalez, M. G., Conright, K. L., & Scheere, A. R. (1982) · Environment International · doi:10.1016/0160-4120(82)90047-2 · Cited by 42 · cited 8×
“Little et al (38) simulated the VOC emissions from new carpets using the assumption that the VOCs originate predominately in a uniform slab of polymer backing material.”
BackgroundInfluentialEvaluation of Low-VOC Latex Paints
Chang, J. C. S., Fortmann, R. C., Roache, N. F., & Lao, H. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00004.x · Cited by 40 · cited 1×
“Although substantial progress has been made to characterize emissions from building products, paints, and equipment, predictive models reflecting complexity of interactions, variability, and human response lag behind (24, 25, 26).”
Background(1996) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(96)82620-8 · Cited by 26 · cited 1×
“Interpreting results requires knowledge about test protocols (42, 43).”
BackgroundResidential pollutants and ventilation strategies: Moisture and combustion products
Hadlich, D. E., & Grimsrud, D. T. (1999) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 11
Cited by
David, E., & Niculescu, V.-C. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182413147 · Cited by 510
Zhai, Z. J., Zhang, Z., Zhang, W., & Chen, Q. Y. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10391459 · Cited by 457
Self-citationTen questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268
Verdier, T., Coutand, M., Bertron, A., & Roques, C. (2014) · Coatings · doi:10.3390/coatings4030670 · Cited by 231
“, aerial particles, such as spores, allergens, toxins and other metabolites, that can be serious health hazards to occupants [15–23].”
BackgroundA review of indoor microbial growth across building materials and sampling and analysis methods
Verdier, T., Coutand, M., Bertron, A., & Roques, C. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.05.030 · Cited by 214
“The chemical composition of the substrate, here building materials, also influences growth, as it is a potential nutrient supply for microorganisms [8,32,36,37].”
Background
Metadata
- Authors
- Spengler, J. D., & Chen, Q.
- Venue
- Annual Review of Energy and the Environment
- Publisher
- Annual Reviews
- Published
- 2000-11
- Volume
- 25
- Issue
- 1
- Pages
- 567-600
- ISSN
- 1056-3466 (ISSN-L)
- OpenAlex
- W2144487360
- Cited by
- 194
- References
- 31
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.