The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Abstract
Airborne transmission of infectious agents and associations of indoor air pollutants with respiratory illnesses are well documented. We hypothesized that energy conservation measures that tighten buildings also increase risks of respiratory infection among building occupants. At four Army training centers during a 47-month period, incidence rates of febrile acute respiratory disease were compared between basic trainees in modern (energy-efficient design and construction) and old barracks. Rates of febrile acute respiratory disease were significantly higher among trainees in modern barracks (adjusted relative risk estimate, 1.51; 95% confidence interval, 1.46 to 1.56), and relative risks were consistent at the four centers. These results support the hypothesis that tight buildings with closed ventilation systems significantly increase risks of respiratory-transmitted infection among congregated, immunologically susceptible occupants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerosol transmission of rhinovirus colds
Dick, E. C., Jennings, L. C., Mink, K. A., Wartgow, C. D., & Inborn, S. L. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.3.442 · Cited by 280
Cited by
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Adverse health effects of outdoor air pollutants
Curtis, L., Rea, W., Smith-Willis, P., Fenyves, E., & Pan, Y. (2006) · Environment International · doi:10.1016/j.envint.2006.03.012 · Cited by 579
Fisk, W. J. (2000) · Annual Review of Energy and the Environment · doi:10.1146/annurev.energy.25.1.537 · Cited by 557
Metadata
- Authors
- Brundage, J. F.
- Venue
- JAMA: The Journal of the American Medical Association
- Publisher
- American Medical Association (AMA)
- Published
- 1988-04-08
- Volume
- 259
- Issue
- 14
- Pages
- 2108
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2030999457
- Cited by
- 158
- References
- 1
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees. https://app.cochat.ai/papers/10.1001/jama.1988.03720140028029
- The paper
- Brundage, J. F. (1988). Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees. JAMA: The Journal of the American Medical Association. https://doi.org/10.1001/jama.1988.03720140028029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.