X-Ray Tomographic Microscopy (XTM) Using Synchrotron Radiation

Kinney, J H, Nichols, M C·1992·Annual Review of Materials Science

Abstract

The response of a material to an applied load is inherently three-dimen­ sional. Heterogeneous networks of second phases, reinforcing particles, and fibers act to redistribute applied loads into complex, three-dimensional distributions of stresses and strains. Mechanical properties measurements, however, traditionally rely upon oneand two-dimensional analytical tech­ niques to explain what are, in reality, three-dimensional responses. A load­ displacement curve is an example of a one-dimensional measurement, which is often used to measure global deformation in a sample, and to infer micro mechanical mechanisms that might be operating during deformation. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) are examples of essentially two-dimensional techniques that can be used to provide evidence for the origin of failure and whether

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1146/annurev.ms.22.080192.001005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 245

Metadata

Authors
Kinney, J. H., & Nichols, M. C.
Venue
Annual Review of Materials Science
Published
1992-08
Volume
22
Issue
1
Pages
121-152
ISSN
0084-6600 (ISSN-L)
OpenAlex
W2181108849
Cited by
245
References
0
FWCI
8.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: X-Ray Tomographic Microscopy (XTM) Using Synchrotron Radiation. https://app.cochat.ai/papers/10.1146/annurev.ms.22.080192.001005
The paper
Kinney, J. H., & Nichols, M. C. (1992). X-Ray Tomographic Microscopy (XTM) Using Synchrotron Radiation. Annual Review of Materials Science. https://doi.org/10.1146/annurev.ms.22.080192.001005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.