Optical Methods for Monitoring Neuron Activity
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A method for monitoring neuron activity that does not require electrodes might be useful in situations where the use of electrodes is difficult because of neuron size, geometry, or number. A neuron will interact with electromagnetic or ultrasonic radiation in many different ways. If any one of these interactions changes during neuron activity, then its measurement could be used as a noninvasive method for monitoring that activity. The use of an optical method was suggested by the discovery of changes in light scattering, birefringence, and fluorescence that accompany the action potential (Co hen, Keynes & Hille 1968, Tasaki et al 1968). However, because the signal-to-noise ratios of these signals were too small to be used to monitor activity in individual neurons, a search for larger signals was initiated (Davila, Cohen & Waggoner 1 972, Cohen, 1973). At present, the largest signals are changes in absorption of light by axons stained with the merocyanine dyes (Ross et al 1977, Salzberg et al 1977), whose structures are shown in Figure 1. These absorption signals are about 100 times larger than the largest signal available in 1 971. The first part of this article presents evidence that the absorption changes of these dyes somehow result from the changes in membrane potential rather than from the ionic currents or the increases in membrane permeability that occur during an action potential. This is followed by a review of our efforts to find larger signals. The use of a dye may lead to pharmacologic effects or to photodynamic damage, and both possible problems are discussed briefly. Because the light from many different parts of a preparation can be measured simultaneously, it should, in principle, be possible to monitor activity in many neurons at once. It is this application that has inspired our interest in optical
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sims, P. J., Waggoner, A. S., Wang, C.-H., & Hoffman, J. F. (1974) · Biochemistry · doi:10.1021/bi00713a022 · Cited by 951
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580
Optical measurement of membrane potential
Cohen, L. B., & Salzberg, B. M. (1978) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/3-540-08907-1_2 · Cited by 522
Self-citationLight scattering and birefringence changes during nerve activity
COHEN, L. B., KEYNES, R. D., & HILLE, B. (1968) · Nature · doi:10.1038/218438a0 · Cited by 479
Self-citationChanges in axon fluorescence during activity: Molecular probes of membrane potential
Cohen, L. B., Salzberg, B. M., Davila, H. V., Ross, W. N., Landowne, D., Waggoner, A. S., & Wang, C. H. (1974) · The Journal of Membrane Biology · doi:10.1007/bf01869968 · Cited by 455
Self-citationOptical probes of membrane potential
Waggoner, A. (1976) · The Journal of Membrane Biology · doi:10.1007/bf01869143 · Cited by 358
Changes in fluorescence, turbidity, and birefringence associated with nerve excitation.
Tasaki, I., Watanabe, A., Sandlin, R., & Carnay, L. (1968) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.61.3.883 · Cited by 352
Optical Recording of Impulses in Individual Neurones of an Invertebrate Central Nervous System
SALZBERG, B. M., DAVILA, H. V., & COHEN, L. B. (1973) · Nature · doi:10.1038/246508a0 · Cited by 240
Self-citationDAVILA, H. V., SALZBERG, B. M., COHEN, L. B., & WAGGONER, A. S. (1973) · Nature New Biology · doi:10.1038/newbio241159a0 · Cited by 183
Self-citationSimultaneous recording from several neurones in an invertebrate central nervous system
Grinvald, A., Salzberg, B. M., & Cohen, L. B. (1977) · Nature · doi:10.1038/268140a0 · Cited by 97
Self-citationTRANSIENT CHANGES IN EXTRINSIC FLUORESCENCE OF NERVE PRODUCED BY ELECTRIC STIMULATION
Tasaki, I., Carnay, L., & Watanabe, A. (1969) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.64.4.1362 · Cited by 61
Fluorescent Probes in Nerve Membranes
Conti, F. (1975) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.04.060175.001443 · Cited by 57
Fluorescence of squid axon membrane labelled with hydrophobic probes
Tasaki, I., Watanabe, A., & Hallett, M. (1972) · The Journal of Membrane Biology · doi:10.1007/bf01868097 · Cited by 53
Changes in Extrinsic Fluorescence in Squid Axons during Voltage-Clamp
Conti, F., & Tasaki, I. (1970) · Science · doi:10.1126/science.169.3952.1322 · Cited by 37
Cited by
VSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618
“What does the dye measure in vivo? In simple preparations, when single cells can be visualized, the dye signal looks just like an intracellular recordin”
BackgroundSelf-citationSoft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
Are central pattern generators understandable?
Selverston, A. I. (1980) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00006580 · Cited by 319
Optical mapping of electrical activity in rat somatosensory and visual cortex
Orbach, H., Cohen, L., & Grinvald, A. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-07-01886.1985 · Cited by 282
Self-citationImproved fluorescent probes for the measurement of rapid changes in membrane potential
Grinvald, A., Hildesheim, R., Farber, I. C., & Anglister, L. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84520-7 · Cited by 258
Self-citation
Metadata
- Authors
- Cohen, L. B., Salzberg, B. M., & Grinvald, A.
- Venue
- Annual Review of Neuroscience
- Publisher
- Annual Reviews
- Published
- 1978-03
- Volume
- 1
- Issue
- 1
- Pages
- 171-182
- ISSN
- 0147-006X (ISSN-L)
- 1545-4126
- OpenAlex
- W2149316724
- Cited by
- 185
- References
- 14
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.