Surface Plasmon Resonance Imaging Measurements of Ultrathin Organic Films
Abstract
The surface-sensitive optical technique of surface plasmon resonance (SPR) imaging is used to characterize ultrathin organic and biopolymer films at metal interfaces in a spatially resolved manner. Because of its high surface sensitivity and its ability to measure in real time the interaction of unlabeled biological molecules with arrays of surface-bound species, SPR imaging has the potential to become a powerful tool in biomolecular investigations. Recently, SPR imaging has been successfully implemented in the characterization of supported lipid bilayer films, the monitoring of antibody-antigen interactions at surfaces, and the study of DNA hybridization adsorption. The following is included in this review: (a) an introduction to the principles of surface plasmon resonance, (b) the details of SPR imaging instrumental design, (c) a short discussion concerning resolution, sensitivity, and quantitation in SPR imaging, (d) the details of DNA array fabrication on chemically modified gold surfaces, and (e) two examples that demonstrate the application of the SPR imaging technique to the study of protein-DNA interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Light-Directed, Spatially Addressable Parallel Chemical Synthesis
Fodor, S. P. A., Read, J. L., Pirrung, M. C., Stryer, L., Lu, A. T., & Solas, D. (1991) · Science · doi:10.1126/science.1990438 · Cited by 2,696
Characterization of DNA Probes Immobilized on Gold Surfaces
Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9719586 · Cited by 1,541
Light-generated oligonucleotide arrays for rapid DNA sequence analysis.
Pease, A. C., Solas, D., Sullivan, E. J., Cronin, M. T., Holmes, C. P., & Fodor, S. P. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.5022 · Cited by 1,367
INTERFACES AND THIN FILMS AS SEEN BY BOUND ELECTROMAGNETIC WAVES
Knoll, W. (1998) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.49.1.569 · Cited by 1,011
Solid phase peptide synthesis; a practical approach
(1991) · Comparative Biochemistry and Physiology Part A: Physiology · doi:10.1016/0300-9629(91)90598-7 · Cited by 762
Rothenhäusler, B., & Knoll, W. (1988) · Nature · doi:10.1038/332615a0 · Cited by 757
Maskless fabrication of light-directed oligonucleotide microarrays using a digital micromirror array
Singh-Gasson, S., Green, R. D., Yue, Y., Nelson, C., Blattner, F., Sussman, M. R., & Cerrina, F. (1999) · Nature Biotechnology · doi:10.1038/13664 · Cited by 733
Hansen, W. N. (1968) · Journal of the Optical Society of America · doi:10.1364/josa.58.000380 · Cited by 729
Solid Phase Peptide Synthesis — A Practical Approach
Sherrington, D. C. (1990) · Reactive Polymers · doi:10.1016/0923-1137(90)90086-j · Cited by 644
Biospecific interaction analysis using biosensor technology
Malmqvist, M. (1993) · Nature · doi:10.1038/361186a0 · Cited by 532
Peterlinz, K. A., Georgiadis, R. M., Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja964326c · Cited by 477
The single-stranded DNA-binding protein of Escherichia coli
Meyer, R. R., & Laine, P. S. (1990) · Microbiological Reviews · doi:10.1128/mmbr.54.4.342-380.1990 · Cited by 459
Patterned Self-Assembled Monolayers and Meso-Scale Phenomena
Kumar, A., Abbott, N. L., Biebuyck, H. A., Kim, E., & Whitesides, G. M. (1995) · Accounts of Chemical Research · doi:10.1021/ar00053a003 · Cited by 400
Refractive Index of Water and Its Dependence on Wavelength, Temperature, and Density
Thormählen, I., Straub, J., & Grigull, U. (1985) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555743 · Cited by 367
Mispair specificity of methyl-directed DNA mismatch correction in vitro.
Su, S. S., Lahue, R. S., Au, K. G., & Modrich, P. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)68718-6 · Cited by 337
Brockman, J. M., Frutos, A. G., & Corn, R. M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991608e · Cited by 336
Self-citationFrey, B. L., & Corn, R. M. (1996) · Analytical Chemistry · doi:10.1021/ac9605861 · Cited by 313
Self-citationJordan, C. E., Frutos, A. G., Thiel, A. J., & Corn, R. M. (1997) · Analytical Chemistry · doi:10.1021/ac9709763 · Cited by 281
Self-citationThiel, A. J., Frutos, A. G., Jordan, C. E., Corn, R. M., & Smith, L. M. (1997) · Analytical Chemistry · doi:10.1021/ac9708001 · Cited by 269
Self-citationHaeussling, L., Ringsdorf, H., Schmitt, F., et al. (1991) · Langmuir · doi:10.1021/la00057a001 · Cited by 244
Jordan, C. E., & Corn, R. M. (1997) · Analytical Chemistry · doi:10.1021/ac961012z · Cited by 216
Self-citationBIAcore for macromolecular interaction
Fivash, M., Towler, E. M., & Fisher, R. J. (1998) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(98)80091-8 · Cited by 205
Replication errors: cha(lle)nging the genome
Jiricny, J. (1998) · The EMBO Journal · doi:10.1093/emboj/17.22.6427 · Cited by 204
Bondeson, K., Frostell‐Karlsson, Å., Fägerstam, L. G., & Magnusson, G. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1484 · Cited by 131
Mismatch Binding Protein-Based Mutation Detection Systems
Wagner, R. E., & Radman, M. (1995) · Methods · doi:10.1006/meth.1995.1025 · Cited by 113
Biotechnological applications of surface plasmon resonance
Silin, V. I., & Plant, A. L. (1997) · Trends in biotechnology · doi:10.1016/s0167-7799(97)01085-8 · Cited by 95
Fisher, R. J., Fivash, M. J., Casas‐Finet, J. R., Bladen, S. V., & McNitt, K. L. (1994) · Methods · doi:10.1006/meth.1994.1015 · Cited by 61
Hanning, A., Roeraade, J., Delrow, J. J., et al. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00323-2 · Cited by 47
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Exploitation of Localized Surface Plasmon Resonance
Hutter, E., & Fendler, J. H. (2004) · Advanced Materials · doi:10.1002/adma.200400271 · Cited by 2,726
Nanoparticles, Proteins, and Nucleic Acids: Biotechnology Meets Materials Science
Niemeyer, C. M. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20011119)40:22<4128::aid-anie4128>3.0.co;2-s · Cited by 2,452
Metadata
- Authors
- Brockman, J. M., Nelson, B. P., & Corn, R. M.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2000-10
- Volume
- 51
- Issue
- 1
- Pages
- 41-63
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2123342482
- Cited by
- 551
- References
- 29
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.