Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record.

Radiation dose in CT.

Rothenberg, L N, Pentlow, K S·1992·RadioGraphics

Abstract

The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiologic procedures. The dose values within a specific section are determined by factors such as voltage, current, scan time, scan field, rotation angle, filtration, collimation, and section thickness and spacing. For routine dose determinations, a pencil ionization chamber is usually employed with a plastic phantom. Dose for a specific patient can be determined with thermoluminescent dosimeters placed on the patient. Multiple-scan procedures normally increase the dose in a specific section by less than a factor of two. Typical multiple-scan average doses are in the range of 40-60 mGy for head scans and 10-40 mGy for body scans. Integral dose, however, is directly proportional to the number of sections in an examination. When examination factors are changed to reduce dose, the image noise increases. An optimum protocol is one that results in a balance between dose and image quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiographics.12.6.1439023

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Rothenberg, L. N., & Pentlow, K. S.
Venue
RadioGraphics
Published
1992-11
Volume
12
Issue
6
Pages
1225-1243
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2144636812
Cited by
192
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiation dose in CT. https://app.cochat.ai/papers/10.1148/radiographics.12.6.1439023
The paper
Rothenberg, L. N., & Pentlow, K. S. (1992). Radiation dose in CT. RadioGraphics. https://doi.org/10.1148/radiographics.12.6.1439023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.