Metal Artifact Reduction Sequence: Early Clinical Applications
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Artifact arising from metal hardware remains a significant problem in orthopedic magnetic resonance imaging. The metal artifact reduction sequence (MARS) reduces the size and intensity of susceptibility artifacts from magnetic field distortion. The sequence, which is based on view angle tilting in combination with increased gradient strength, can be conveniently used in conjunction with any spin-echo sequence and requires no additional imaging time. In patients with persistent pain after femoral neck fracture, the MARS technique allows visualization of marrow adjacent to hip screws, thus enabling diagnosis or exclusion of avascular necrosis. Other applications in the hip include assessment of periprosthetic soft tissues after hip joint replacement surgery, postoperative assessment after resection of bone tumors and reconstruction, and localization of unopacified methyl methacrylate cement prior to hip arthroplasty revision surgery. In the knee, the MARS technique allows visualization of structures adjacent to implanted metal staples, pins, or screws. The technique can significantly improve visualization of periprosthetic bone and soft-tissue structures even in patients who have undergone total knee arthroplasty. In patients with spinal fixation hardware, the MARS technique frequently allows visualization of the vertebral bodies and spinal canal contents. The technique can be helpful after wrist fusion or screw fixation of scaphoid fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting
Cho, Z. H., Kim, D. J., & Kim, Y. K. (1988) · Medical Physics · doi:10.1118/1.596162 · Cited by 217
Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies.
Suh, J. S., Jeong, E. K., Shin, K. H., Cho, J. H., Na, J. B., Kim, D. H., & Han, C. D. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.5.9798849 · Cited by 183
Bellon, E., Haacke, E., Coleman, P., Sacco, D., Steiger, D., & Gangarosa, R. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.6.1271 · Cited by 174
Effect of field strength on susceptibility artifacts in magnetic resonance imaging
Farahani, K., Sinha, U. S., Sinha, S., Chiu, L. C., & Lufkin, R. B. (1990) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(90)90040-i · Cited by 155
Frazzini, V. I., Kagetsu, N. J., Johnson, C. E., & Destian, S. (1997) · Radiology · doi:10.1148/radiology.204.1.9205258 · Cited by 36
Cited by
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
“By replaying the slice select gradient, the off-resonance is limited to the radiofrequency bandwidth, and in-plane distortion is nearly removed [22].”
SEMAC: Slice encoding for metal artifact correction in MRI
Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M., & Hargreaves, B. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21967 · Cited by 392
Stradiotti, P., Curti, A., Castellazzi, G., & Zerbi, A. (2009) · European Spine Journal · doi:10.1007/s00586-009-0998-5 · Cited by 241
Imaging near metal with a MAVRIC‐SEMAC hybrid
Koch, K. M., Brau, A. C., Chen, W., Gold, G. E., Hargreaves, B. A., Koff, M., McKinnon, G. C., Potter, H. G., & King, K. F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22523 · Cited by 230
“Such approaches include single-point imaging (4), prepolarized MRI (5), view-angle tilting (VAT) (6,7), and dual-reversed-gradient acquisitions (8).”
BackgroundMethodInfluentialAn Image-based Approach to Understanding the Physics of MR Artifacts
Morelli, J. N., Runge, V. M., Ai, F., Attenberger, U., Vu, L., Schmeets, S. H., Nitz, W. R., & Kirsch, J. E. (2011) · RadioGraphics · doi:10.1148/rg.313105115 · Cited by 171
“Artifact resulting from the presence of metallic objects, most commonly surgical hardware, not only distorts nearby structures but also may result in signal dropout, depending on the sequence used (24).”
Background
Metadata
- Authors
- Olsen, R. V., Munk, P. L., Lee, M. J., Janzen, D. L., MacKay, A. L., Xiang, Q.-S., & Masri, B.
- Venue
- RadioGraphics
- Published
- 2000-05
- Volume
- 20
- Issue
- 3
- Pages
- 699-712
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2105435975
- Cited by
- 208
- References
- 5
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.