The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multisection CT: Scanning Techniques and Clinical Applications
Abstract
Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section-capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Cited by
Imaging in staging of malignant lymphoma: a systematic review
Kwee, T. C., Kwee, R. M., & Nievelstein, R. A. J. (2008) · Blood · doi:10.1182/blood-2007-07-101899 · Cited by 264
Imaging of neuroendocrine tumors: accuracy of helical CT versus SRS.
Kumbasar, B., Kamel, I. R., Tekes, A., Eng, J., Fishman, E. K., & Wahl, R. L. (2004) · Abdominal Imaging · doi:10.1007/s00261-003-0162-3 · Cited by 84
Lee, W.-J., Ahn, B.-S., & Park, Y.-S. (2012) · Journal of Radiation Protection and Research · doi:10.14407/jrp.2012.37.2.084 · Cited by 4
Metadata
- Authors
- Rydberg, J., Buckwalter, K. A., Caldemeyer, K. S., Phillips, M. D., Conces, D. J., Aisen, A. M., Persohn, S. A., & Kopecky, K. K.
- Venue
- RadioGraphics
- Published
- 2000-11
- Volume
- 20
- Issue
- 6
- Pages
- 1787-1806
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W1998664196
- Cited by
- 363
- References
- 1
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multisection CT: Scanning Techniques and Clinical Applications. https://app.cochat.ai/papers/10.1148/radiographics.20.6.g00nv071787
- The paper
- Rydberg, J., Buckwalter, K. A., Caldemeyer, K. S., Phillips, M. D., Conces, D. J., Aisen, A. M., Persohn, S. A., & Kopecky, K. K. (2000). Multisection CT: Scanning Techniques and Clinical Applications. RadioGraphics. https://doi.org/10.1148/radiographics.20.6.g00nv071787
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.