Performance evaluation of a multi-slice CT system
Abstract
Our purpose in this study was to characterize the performance of a recently introduced multi-slice CT scanner (LightSpeed QX/i, Version 1.0, General Electric Medical Systems) in comparison to a single-slice scanner from the same manufacturer (HiSpeed CT/i, Version 4.0). To facilitate this comparison, a refined definition of pitch is introduced which accommodates multi-slice CT systems, yet maintains the existing relationships between pitch, patient dose, and image quality. The following performance parameters were assessed: radiation and slice sensitivity profiles, low-contrast and limiting spatial resolution, image uniformity and noise, CT number and geometric accuracy, and dose. The multi-slice system was tested in axial (1, 2, or 4 images per gantry rotation) and HQ (Pitch = 0.75) and HS (Pitch = 1.5) helical modes. Axial and helical acquisition speed and limiting spatial resolution (0.8-s exposure) were improved on the multi-slice system. Slice sensitivity profiles, image noise, CT number accuracy and uniformity, and low-contrast resolution were similar. In some HS-helical modes, helical artifacts and geometric distortion were more pronounced with a different appearance. Radiation slice profiles and doses were larger on the multi-slice system at all scan widths. For a typical abdomen and pelvis exam, the central and surface body doses for 5-mm helical scans were higher on the multi-slice system by approximately 50%. The increase in surface CTDI values (with respect to the single-slice system) was greatest for the 4 x 1.25-mm detector configuration (190% for head, 240% for body) and least for the 4 x 5-mm configuration (53% for head, 76% for body). Preliminary testing of version 1.1 software demonstrated reduced doses on the multi-slice scanner, where the increase in body surface CTDI values (with respect to the single-slice system) was 105% for the 4 x 1.25-mm detector configuration and 10% for the 4 x 5-mm configuration. In summary, the axial and HQ-helical modes of the multi-slice system provided excellent image quality and a substantial reduction in exam time and tube loading, although at varying degrees of increased dose relative to the single-slice scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Algorithm for image reconstruction in multi-slice helical CT
Taguchi, K., & Aradate, H. (1998) · Medical Physics · doi:10.1118/1.598230 · Cited by 286
Specification and Acceptance Testing of Computed Tomography Scanners
Lin, P. P., Beck, T., Borras, C., et al. (1993) · doi:10.37206/38 · Cited by 120
Standardized Methods for Measuring Diagnostic X-Ray Exposures
Chu, R. Y. L., Fisher, J., Archer, B. R., Conway, B. J., Goodsitt, M. M., Glaze, S. A., Gray, J. E., & Strauss, K. J. (1990) · doi:10.37206/30 · Cited by 76
Suzuki, A., & Suzuki, M. N. (1978) · Medical Physics · doi:10.1118/1.594445 · Cited by 66
Measurements of computed tomography x‐ray fields utilizing the partial volume effect
Jucius, R. A., & Kambic, G. X. (1980) · Medical Physics · doi:10.1118/1.594696 · Cited by 13
A multiple detector array helical x-ray microtomography system for specimen imaging
Corrigan, N. M., Chavez, A. E., Wisner, E. R., & Boone, J. M. (1999) · Medical Physics · doi:10.1118/1.598662 · Cited by 11
Cited by
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J. (2003) · Radiology · doi:10.1148/radiol.2261011365 · Cited by 405
Mutic, S., Palta, J. R., Butker, E. K., Das, I. J., Huq, M. S., Loo, L.-N. D., Salter, B. J., McCollough, C. H., & Van Dyk, J. (2003) · Medical Physics · doi:10.1118/1.1609271 · Cited by 344
Self-citationNgaile, J. E., Msaki, P., & Kazema, R. (2006) · Journal of Radiological Protection · doi:10.1088/0952-4746/26/2/006 · Cited by 37
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
Metadata
- Authors
- McCollough, C. H., & Zink, F. E.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1999-11
- Volume
- 26
- Issue
- 11
- Pages
- 2223-2230
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2069876858
- Cited by
- 386
- References
- 7
- FWCI
- 21.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance evaluation of a multi-slice CT system. https://app.cochat.ai/papers/10.1118/1.598777
- The paper
- McCollough, C. H., & Zink, F. E. (1999). Performance evaluation of a multi-slice CT system. Medical Physics. https://doi.org/10.1118/1.598777
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.