Multi–Detector Row CT of Mesenteric Ischemia: Can It Be Done?
The DOI matches its Crossref record.
Abstract
Mesenteric ischemia is a complicated disorder whose prevalence in the United States is increasing as the population ages. It is often difficult to diagnose, both clinically and radiologically. In the past, computed tomography (CT) has allowed only limited success in the early detection of ischemia. However, with the introduction of multi-detector row CT and three-dimensional (3D) imaging, it is now possible to perform a detailed CT examination of the small bowel and mesenteric vessels. Multi-detector row CT allows routine studies to be performed much faster than with single-detector CT scanners and makes available new applications, especially in the field of CT angiography. Its increased speed and narrower collimation, coupled with the use of water as an oral contrast agent, improve visualization of the bowel wall and mesenteric vasculature. Multi-detector row CT with 3D reformatting may improve the ability to make an early diagnosis and identify the cause of disease in patients with suspected acute or chronic mesenteric ischemia. In many cases, this examination has eliminated the need for additional imaging studies such as Doppler ultrasonography or angiography. Further investigation will be needed to determine the scope of the utility of multi-detector row CT in this clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wiesner, W., Khurana, B., Ji, H., & Ros, P. R. (2003) · Radiology · doi:10.1148/radiol.2263011540 · Cited by 402
Kirkpatrick, I. D. C., Kroeker, M. A., & Greenberg, H. M. (2003) · Radiology · doi:10.1148/radiol.2291020991 · Cited by 365
CT Diagnosis of Acute Mesenteric Ischemia from Various Causes
Furukawa, A., Kanasaki, S., Kono, N., Wakamiya, M., Tanaka, T., Takahashi, M., & Murata, K. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1138 · Cited by 302
Unchanged high mortality rates from acute occlusive intestinal ischemia: six year review
Kassahun, W. T., Schulz, T., Richter, O., & Hauss, J. (2008) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-007-0263-5 · Cited by 262
Aschoff, A. J., Stuber, G., Becker, B. W., Hoffmann, M. H. K., Schmitz, B. L., Schelzig, H., & Jaeckle, T. (2009) · Abdominal Imaging · doi:10.1007/s00261-008-9392-8 · Cited by 223
Metadata
- Authors
- Horton, K. M., & Fishman, E. K.
- Venue
- RadioGraphics
- Published
- 2001-11
- Volume
- 21
- Issue
- 6
- Pages
- 1463-1473
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2116127425
- Cited by
- 154
- References
- 0
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi–Detector Row CT of Mesenteric Ischemia: Can It Be Done? https://app.cochat.ai/papers/10.1148/radiographics.21.6.g01nv091463
- The paper
- Horton, K. M., & Fishman, E. K. (2001). Multi–Detector Row CT of Mesenteric Ischemia: Can It Be Done? RadioGraphics. https://doi.org/10.1148/radiographics.21.6.g01nv091463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.