CoChat

Evaluation of acute mesenteric ischemia: accuracy of biphasic mesenteric multi-detector CT angiography

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to explore the accuracy of multi-detector row helical CT (MDCT), using a biphasic mesenteric angiography protocol for evaluation of acute mesenteric ischemia (AMI). In total, 79 consecutive patients with clinical signs of AMI underwent contrast enhanced 16- or 40-channel MDCT. MDCT findings were correlated with surgery, endoscopy and clinical outcome. Sensitivity, specificity, and positive and negative predictive values were calculated using the patients in which AMI had been excluded as a control group. In 28 patients the final diagnosis was AMI. In 27 patients (96.4%) MDCT correctly diagnosed AMI (specificity of 97.9%). A sensitivity of 93%, specificity of 100%, and positive and negative predictive values of 100% and 94%, respectively were achieved for the CT findings of visceral artery occlusion, intestinal pneumatosis, portomesenteric venous gas or bowel wall thickening in combination with either portomesenteric thrombosis or solid organ infarction. Our findings suggest that mesenteric MDCT angiography is an accurate tool for fast diagnostic work-up of patients with suspected AMI.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00261-008-9392-8

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 16 references

Cited by

See all 237

Metadata

Authors
Aschoff, A. J., Stuber, G., Becker, B. W., Hoffmann, M. H. K., Schmitz, B. L., Schelzig, H., & Jaeckle, T.
Affiliations
  • Universität Ulm (DE)
  • University Hospital Ulm (DE)
Corresponding author
Aschoff, A. J.
Venue
Abdominal Imaging
Published
2008-04-19
Volume
34
Issue
3
Pages
345-357
ISSN
  • 0942-8925 (ISSN-L)
  • 1432-0509
OpenAlex
W2017712133
Cited by
223
References
16
Citations by year
2026: 5 · 2025: 7 · 2024: 6 · 2023: 17 · 2022: 15 · 2021: 8 · 2020: 14 · 2019: 8 · 2018: 12 · 2017: 13 · 2016: 10 · 2015: 18 · 2014: 19 · 2013: 14 · 2012: 19
FWCI
13.00
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Abdominal Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Abdominal vascular conditions and treatments
  • Health Sciences › Medicine › Surgery › Omental and Epiploic Conditions
  • Health Sciences › Medicine › Emergency Medicine › Appendicitis Diagnosis and Management
Keywords
acute mesenteric ischemia, diagnostic accuracy, visceral artery occlusion, pneumatosis intestinalis, bowel wall thickening, non-invasive diagnosis
MeSH terms
Acute Disease, Adolescent, Adult, Aged, Aged, 80 and over, Contrast Media, Female, Humans, Iopamidol, Ischemia, Male, Mesenteric Arteries, Mesenteric Vascular Occlusion, Middle Aged, Radiographic Image Enhancement, Retrospective Studies, Sensitivity and Specificity, Reproducibility of Results, Tomography, Spiral Computed, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of acute mesenteric ischemia: accuracy of biphasic mesenteric multi-detector CT angiography. https://app.cochat.ai/papers/10.1007/s00261-008-9392-8
The paper
Aschoff, A. J., Stuber, G., Becker, B. W., Hoffmann, M. H. K., Schmitz, B. L., Schelzig, H., & Jaeckle, T. (2009). Evaluation of acute mesenteric ischemia: accuracy of biphasic mesenteric multi-detector CT angiography. Abdominal Imaging. https://doi.org/10.1007/s00261-008-9392-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.