The DOI matches its Crossref record.
Advanced Hepatic Ablation Technique for Creating Complete Cell Death: Irreversible Electroporation
Abstract
PURPOSE: To evaluate the effectiveness of irreversible electroporation (IRE) in hepatic tissue ablation and the radiologic-pathologic correlation of IRE-induced cell death. MATERIALS AND METHODS: On approval of the animal research committee, 16 Yorkshire pigs underwent ultrasonography (US)-guided IRE of normal liver. A total of 55 ablation zones were created, which were imaged with US, magnetic resonance (MR) imaging, and computed tomography (CT) and evaluated with immunohistochemical analysis, including hematoxylin-eosin (H-E), Von Kossa, and von Willibrand factor (vWF) staining and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) assay. RESULTS: At gross section examination, the mean diameter of the ablation zones was 33.5 mm + or - 3.0 (standard deviation) and was achieved in 6.9 minutes (mean total procedure time per ablation), with a mean difference of 2.5 mm + or - 3.6 between US and gross section measurements (r = 0.804). No complications were seen in any of the 16 animals. IRE ablation zones were well characterized with US, CT, and MR imaging, and real-time monitoring was feasible with US. H-E, Von Kossa, and vWF staining showed complete cell death, with a sharply demarcated treatment area. Bile ducts and vessels were completely preserved. Areas of complete cell death were stained positive for apoptotic markers (TUNEL, BCL-2 oncoprotein), suggesting involvement of the apoptotic process in the pathophysiology of cell death caused by IRE. CONCLUSION: In an animal model, IRE proved to be a fast, safe, and potent ablative method, causing complete tissue death by means of apoptosis. Cell death is seen with full preservation of periablative zone structures, including blood vessels, bile ducts, and neighboring nonablated tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sano, M. B., Neal, R. E., Garcia, P. A., Gerber, D., Robertson, J., & Davalos, R. V. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-83 · Cited by 117
Irreversible electroporation (NanoKnife) in cancer treatment
Jourabchi, N., Beroukhim, K., Tafti, B. A., Kee, S. T., & Lee, E. W. (2014) · Gastrointestinal Intervention · doi:10.1016/j.gii.2014.02.002 · Cited by 99
Self-citation
Metadata
- Authors
- Lee, E. W., Chen, C., Prieto, V. E., Dry, S. M., Loh, C. T., & Kee, S. T.
- Venue
- Radiology
- Published
- 2010-05
- Volume
- 255
- Issue
- 2
- Pages
- 426-433
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2146135137
- Cited by
- 330
- References
- 0
- FWCI
- 18.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced Hepatic Ablation Technique for Creating Complete Cell Death: Irreversible Electroporation. https://app.cochat.ai/papers/10.1148/radiol.10090337
- The paper
- Lee, E. W., Chen, C., Prieto, V. E., Dry, S. M., Loh, C. T., & Kee, S. T. (2010). Advanced Hepatic Ablation Technique for Creating Complete Cell Death: Irreversible Electroporation. Radiology. https://doi.org/10.1148/radiol.10090337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.