Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 519

The DOI matches its Crossref record.

Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results

Athanasiou, Alexandra, Tardivon, Anne, Tanter, Mickael, Sigal-Zafrani, Brigitte, Bercoff, Jeremy, Deffieux, Thomas, Gennisson, Jean-Luc, Fink, Mathias, Neuenschwander, Sylvia·2010·Radiology

Abstract

PURPOSE: To determine the appearance of breast lesions at quantitative ultrasonographic (US) elastography by using supersonic shear imaging (SSI) and to assess the correlation between quantitative values of lesion stiffness and pathologic results, which were used as the reference standard. MATERIALS AND METHODS: This study was approved by the French National Committee for the Protection of Patients Participating in Biomedical Research Programs. All patients provided written informed consent. Conventional US and SSI quantitative elastography were performed in 46 women (mean age, 57.6 years; age range, 38-71 years) with 48 breast lesions (28 benign, 20 malignant; mean size, 14.7 mm); pathologic results were available in all cases. Quantitative lesion elasticity was measured in terms of the Young modulus (in kilopascals). Sensitivity, specificity, and area under the curve were obtained by using a receiver operating characteristic curve analysis to assess diagnostic performance. RESULTS: All breast lesions were detected at SSI. Malignant lesions exhibited a mean elasticity value of 146.6 kPa +/- 40.05 (standard deviation), whereas benign ones had an elasticity value of 45.3 kPa +/- 41.1 (P < .001). Complicated cysts were differentiated from solid lesions because they had elasticity values of 0 kPa (no signal was retrieved from liquid areas). CONCLUSION: SSI provides quantitative elasticity measurements, thus adding complementary information that potentially could help in breast lesion characterization with B-mode US.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10090385

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 519

Metadata

Authors
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S.
Venue
Radiology
Published
2010-07
Volume
256
Issue
1
Pages
297-303
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2153770867
Cited by
519
References
0
FWCI
32.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results. https://app.cochat.ai/papers/10.1148/radiol.10090385
The paper
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010). Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results. Radiology. https://doi.org/10.1148/radiol.10090385

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.