The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Abstract
PURPOSE: To determine the appearance of breast lesions at quantitative ultrasonographic (US) elastography by using supersonic shear imaging (SSI) and to assess the correlation between quantitative values of lesion stiffness and pathologic results, which were used as the reference standard. MATERIALS AND METHODS: This study was approved by the French National Committee for the Protection of Patients Participating in Biomedical Research Programs. All patients provided written informed consent. Conventional US and SSI quantitative elastography were performed in 46 women (mean age, 57.6 years; age range, 38-71 years) with 48 breast lesions (28 benign, 20 malignant; mean size, 14.7 mm); pathologic results were available in all cases. Quantitative lesion elasticity was measured in terms of the Young modulus (in kilopascals). Sensitivity, specificity, and area under the curve were obtained by using a receiver operating characteristic curve analysis to assess diagnostic performance. RESULTS: All breast lesions were detected at SSI. Malignant lesions exhibited a mean elasticity value of 146.6 kPa +/- 40.05 (standard deviation), whereas benign ones had an elasticity value of 45.3 kPa +/- 41.1 (P < .001). Complicated cysts were differentiated from solid lesions because they had elasticity values of 0 kPa (no signal was retrieved from liquid areas). CONCLUSION: SSI provides quantitative elasticity measurements, thus adding complementary information that potentially could help in breast lesion characterization with B-mode US.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Pathology and Genetics of Tumours of the Breast and Female Genital Organs
Tavassoli, F. A., & Devilee, P. (2003) · International Agency for Research on Cancer eBooks · Cited by 2,800
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationBreast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.
Stavros, A. T., Thickman, D., Rapp, C. L., Dennis, M. A., Parker, S. H., & Sisney, G. A. (1995) · Radiology · doi:10.1148/radiology.196.1.7784555 · Cited by 1,780
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Self-citationBI-RADS Lexicon for US and Mammography: Interobserver Variability and Positive Predictive Value
Lazarus, E., Mainiero, M. B., Schepps, B., Koelliker, S. L., & Livingston, L. S. (2006) · Radiology · doi:10.1148/radiol.2392042127 · Cited by 511
In vivo breast tumor detection using transient elastography
Bercoff, J., Chaffai, S., Tanter, M., Sandrin, L., Catheline, S., Fink, M., Gennisson, J. L., & Meunier, M. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00978-5 · Cited by 341
Self-citation
Cited by
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationCosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Self-citationWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 3: Liver
Ferraioli, G., Filice, C., Castera, L., Choi, B. I., Sporea, I., Wilson, S. R., Cosgrove, D., Dietrich, C. F., Amy, D., Bamber, J. C., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.007 · Cited by 879
Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017) · RadioGraphics · doi:10.1148/rg.2017160116 · Cited by 729
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
Self-citationWFUMB Guidelines and Recommendations for Clinical Use of Ultrasound Elastography: Part 2: Breast
Barr, R. G., Nakashima, K., Amy, D., Cosgrove, D., Farrokh, A., Schafer, F., Bamber, J. C., Castera, L., Choi, B. I., Chou, Y.-H., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.008 · Cited by 474
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
Evans, A., Whelehan, P., Thomson, K., McLean, D., Brauer, K., Purdie, C., Jordan, L., Baker, L., & Thompson, A. (2010) · Breast Cancer Research · doi:10.1186/bcr2787 · Cited by 450
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Bavu, É., Gennisson, J.-L., Couade, M., Bercoff, J., Mallet, V., Fink, M., Badel, A., Vallet-Pichard, A., Nalpas, B., Tanter, M., et al. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.016 · Cited by 415
Self-citationShear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
Chang, J. M., Moon, W. K., Cho, N., Yi, A., Koo, H. R., Han, W., Noh, D.-Y., Moon, H.-G., & Kim, S. J. (2011) · Breast Cancer Research and Treatment · doi:10.1007/s10549-011-1627-7 · Cited by 347
Breast Ultrasonography: State of the Art
Hooley, R. J., Scoutt, L. M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13121606 · Cited by 324
Evans, A., Whelehan, P., Thomson, K., McLean, D., Brauer, K., Purdie, C., Baker, L., Jordan, L., Rauchhaus, P., & Thompson, A. (2012) · Radiology · doi:10.1148/radiol.12111317 · Cited by 268
Spatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
Metadata
- Authors
- Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S.
- Venue
- Radiology
- Published
- 2010-07
- Volume
- 256
- Issue
- 1
- Pages
- 297-303
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2153770867
- Cited by
- 519
- References
- 18
- FWCI
- 32.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.