The DOI matches its Crossref record.
Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
Abstract
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality and clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges is with intravenous contrast medium administration and scan timing. In this article, contrast medium pharmacokinetics and patient, contrast medium, and CT scanning factors associated with contrast enhancement and scan timing are presented and discussed. Published data from clinical studies of contrast medium and physiology are reviewed and interpreted. Computer simulation data are analyzed to provide an in-depth analysis of various factors associated with contrast enhancement and scan timing. On the basis of basic principles and analysis of the factors, clinical considerations and modifications to protocol design that are necessary to optimize contrast enhancement for common clinical CT applications are proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Transport properties of pancreatic cancer describe gemcitabine delivery and response
Koay, E. J., Truty, M. J., Cristini, V., Thomas, R. M., Chen, R., Chatterjee, D., Kang, Y., Bhosale, P. R., Tamm, E. P., Crane, C. H., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci73455 · Cited by 184
Wang, L., Shi, Y., Jiang, J., Li, C., Zhang, H., Zhang, X., Jiang, T., Wang, L., Wang, Y., & Feng, L. (2022) · Small · doi:10.1002/smll.202203678 · Cited by 71
Polk, S. L., Choi, J. W., McGettigan, M. J., Rose, T., Ahmed, A., Kim, J., Jiang, K., Balagurunathan, Y., Qi, J., Farah, P. T., et al. (2020) · World Journal of Gastroenterology · doi:10.3748/wjg.v26.i24.3458 · Cited by 48
Metadata
- Authors
- Bae, K. T.
- Venue
- Radiology
- Published
- 2010-07
- Volume
- 256
- Issue
- 1
- Pages
- 32-61
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2136860319
- Cited by
- 1,067
- References
- 0
- FWCI
- 26.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches. https://app.cochat.ai/papers/10.1148/radiol.10090908
- The paper
- Bae, K. T. (2010). Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches. Radiology. https://doi.org/10.1148/radiol.10090908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.