The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Microbubble-enhanced US in Body Imaging: What Role?
Abstract
Contrast agents for ultrasonography (US) comprise microscopic bubbles of gas in an encapsulating shell. They are unique in that they interact with the imaging process, oscillating in response to a low-intensity ultrasound field and disrupting in response to a high-intensity field. New contrast-specific imaging modes allow US to show exquisite vascularity and tissue perfusion in real time and with excellent spatial resolution. In Europe, Asia, and Canada, to name only the most obvious, characterization of focal liver masses is the first and best established use of contrast-enhanced (CE) US, allowing for the noninvasive diagnosis of commonly encountered liver masses with comparable accuracy to that of computed tomography and magnetic resonance studies. CE US is a preferred modality for the difficult task of diagnosis of liver nodules detected on surveillance scans in those at risk for hepatocellular carcinoma. Newer body applications include the guidance of ablative intervention, monitoring activity of bowel inflammation in Crohn disease, characterization of kidney masses, especially cystic renal cell carcinoma, diagnosis of prostate cancer, and monitoring the response of tumors to antivascular drug therapies. Microbubble contrast agents are easy to use and robust; their use poses no risk of nephrotoxicity and requires no ionizing radiation. CE US plays a vital and expanding role that improves management and patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Management of Hepatocellular Carcinoma *
Bruix, J., & Sherman, M. (2005) · Hepatology · doi:10.1002/hep.20933 · Cited by 5,857
Clinical Management of Hepatocellular Carcinoma. Conclusions of the Barcelona-2000 EASL Conference
Bruix, J., Sherman, M., Llovet, J. M., Beaugrand, M., Lencioni, R., Burroughs, A. K., Christensen, E., Pagliaro, L., Colombo, M., & Rodés, J. (2001) · Journal of Hepatology · doi:10.1016/s0168-8278(01)00130-1 · Cited by 4,089
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Clinical translation of angiogenesis inhibitors
Kerbel, R., & Folkman, J. (2002) · Nature Reviews Cancer · doi:10.1038/nrc905 · Cited by 1,517
The safety of Sonovue® in abdominal applications: Retrospective analysis of 23188 investigations
Piscaglia, F., & Bolondi, L. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.05.031 · Cited by 747
Quaia, E., Calliada, F., Bertolotto, M., Rossi, S., Garioni, L., Rosa, L., & Pozzi-Mucelli, R. (2004) · Radiology · doi:10.1148/radiol.2322031401 · Cited by 479
Trends in Adverse Events After IV Administration of Contrast Media
Cochran, S. T., Bomyea, K., & Sayre, J. W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.6.1761385 · Cited by 358
Encapsulated ultrasound microbubbles: Therapeutic application in drug/gene delivery
Liu, Y., Miyoshi, H., & Nakamura, M. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.018 · Cited by 319
Hynynen, K., McDannold, N., Vykhodtseva, N., Raymond, S., Weissleder, R., Jolesz, F. A., & Sheikov, N. (2006) · Journal of Neurosurgery · doi:10.3171/jns.2006.105.3.445 · Cited by 314
Kitano, M., Kudo, M., Maekawa, K., Suetomi, Y., Sakamoto, H., Fukuta, N., Nakaoka, R., & Kawasaki, T. (2004) · Gut · doi:10.1136/gut.2003.029934 · Cited by 255
Ultrasound-mediated cavitation thresholds of liquid perfluorocarbon droplets in vitro
Giesecke, T., & Hynynen, K. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00980-3 · Cited by 207
Burns, P. N., & Wilson, S. R. (2007) · Radiology · doi:10.1148/radiol.2421051006 · Cited by 199
Self-citationLassau, N., Lamuraglia, M., Chami, L., Leclère, J., Bonvalot, S., Terrier, P., Roche, A., & Le Cesne, A. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.1192 · Cited by 196
Evaluation of tumor angiogenesis with US: Imaging, Doppler, and contrast agents
Ferrara, K. W., Merritt, C. R. B., Burns, P. N., Stuart Foster, F., Mattrey, R. F., & Wickline, S. A. (2000) · Academic Radiology · doi:10.1016/s1076-6332(00)80631-5 · Cited by 186
Self-citationKitzman, D. W., Goldman, M. E., Gillam, L. D., Cohen, J. L., Aurigemma, G. P., & Gottdiener, J. S. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01050-x · Cited by 166
Targeted ultrasound contrast agent for molecular imaging of inflammation in high-shear flow
Klibanov, A. L., Rychak, J. J., Yang, W. C., Alikhani, S., Li, B., Acton, S., Lindner, J. R., Ley, K., & Kaul, S. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.113 · Cited by 166
Leong-Poi, H., Kuliszewski, M. A., Lekas, M., Sibbald, M., Teichert-Kuliszewska, K., Klibanov, A. L., Stewart, D. J., & Lindner, J. R. (2007) · Circulation Research · doi:10.1161/circresaha.107.148676 · Cited by 165
Quaia, E., D’Onofrio, M., Palumbo, A., Rossi, S., Bruni, S., & Cova, M. A. (2006) · European Radiology · doi:10.1007/s00330-006-0192-7 · Cited by 157
Serra, C., Menozzi, G., Labate, A. M. M., Giangregorio, F., Gionchetti, P., Beltrami, M., Robotti, D., Fornari, F., & Cammarota, T. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.11.027 · Cited by 155
Wink, M. H., Frauscher, F., Cosgrove, D. O., Chapelon, J., Palwein, L., Mitterberger, M., Harvey, C., Rouvière, O., de la Rosette, J. J. M. C. H., & Wijkstra, H. (2008) · European Urology · doi:10.1016/j.eururo.2008.06.057 · Cited by 123
Kaufman, D. W., & Anaphylaxis, T. I. C. S. O. S. (2003) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.822 · Cited by 119
Neuroendocrine pancreatic tumor
D’Onofrio, M., Mansueto, G., Falconi, M., & Procacci, C. (2004) · Abdominal Imaging · doi:10.1007/s00261-003-0097-8 · Cited by 102
Emerging roles for contrast-enhanced ultrasound
Weskott, H. P. (2008) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2008-1062 · Cited by 75
Cellular and molecular imaging with targeted contrast ultrasound.
Behm, C. Z., & Lindner, J. R. (2006) · PubMed · Cited by 42
Molecular and Cellular Imaging with Targeted Contrast Ultrasound
Christiansen, J., & Lindner, J. R. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.844260 · Cited by 35
Cited by
Omata, M., Cheng, A.-L., Kokudo, N., Kudo, M., Lee, J. M., Jia, J., Tateishi, R., Han, K.-H., Chawla, Y. K., Shiina, S., et al. (2017) · Hepatology International · doi:10.1007/s12072-017-9799-9 · Cited by 2,171
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Sidhu, P., Cantisani, V., Dietrich, C., Gilja, O., Saftoiu, A., Bartels, E., Bertolotto, M., Calliada, F., Clevert, D.-A., Cosgrove, D., et al. (2018) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0586-1107 · Cited by 1,086
Piscaglia, F., Nolsøe, C., Dietrich, C., Cosgrove, D., Gilja, O., Bachmann Nielsen, M., Albrecht, T., Barozzi, L., Bertolotto, M., Catalano, O., et al. (2011) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0031-1281676 · Cited by 1,082
Dietrich, C. F., Nolsøe, C. P., Barr, R. G., Berzigotti, A., Burns, P. N., Cantisani, V., Chammas, M. C., Chaubal, N., Choi, B. I., Clevert, D.-A., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.04.030 · Cited by 498
Self-citation
Metadata
- Authors
- Wilson, S. R., & Burns, P. N.
- Venue
- Radiology
- Published
- 2010-10
- Volume
- 257
- Issue
- 1
- Pages
- 24-39
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2139080209
- Cited by
- 470
- References
- 26
- FWCI
- 23.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.