The DOI matches its Crossref record.
Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique
Abstract
PURPOSE: To compare visualization of subtle normal and abnormal findings at computed tomography (CT) of the chest for diffuse lung disease with images reconstructed with filtered back projection and adaptive statistical iterative reconstruction (ASIR) techniques. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, 24 patients underwent 64-section multi-detector row CT of the chest for evaluation of diffuse lung disease. Scanning parameters included a pitch of 0.984:1 and 120 kVp in thin-section mode, with 2496 views per rotation compared with 984 views acquired for normal mode. The 0.625-mm-thick images were reconstructed with filtered back projection, ASIR, and ASIR high-definition (ASIR-HD) kernels. Two thoracic radiologists independently assessed the filtered back projection, ASIR, and ASIR-HD images for small anatomic details (interlobular septa, centrilobular region, and small bronchi and bronchioles), abnormal findings (reticulation, tiny nodules, altered attenuation, bronchiectasis), image quality (graded by using a six-point scale, where 1 = excellent image quality, and 5 = interpretation impossible), image noise, and artifacts. Data were tabulated for statistical testing. RESULTS: For visualization of normal and pathologic structures, CT image series reconstructed with ASIR-HD were rated substantially better than those reconstructed with filtered back projection and ASIR (P < .001). ASIR-HD images were superior to filtered back projection images in 15 of 24 (62%) patients for visualization of normal structures and in 24 of 24 (100%) patients for pathologic findings. ASIR-HD was superior to ASIR in three of 24 (12%) images for normal anatomic findings and in seven of 24 (29%) images for pathologic evaluation. None of the images in the three groups were rated as unacceptable for noise (P < .001). CONCLUSION: ASIR-HD reconstruction results in superior visualization of subtle and tiny anatomic structures and lesions in diffuse lung disease compared with ASIR and filtered back projection reconstructions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Imaging diagnosis of pancreatic cancer: A state-of-the-art review
Lee, E. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i24.7864 · Cited by 401
Singh, S., Kalra, M. K., Gilman, M. D., Hsieh, J., Pien, H. H., Digumarthy, S. R., & Shepard, J.-A. O. (2011) · Radiology · doi:10.1148/radiol.11101450 · Cited by 344
Self-citationKatsura, M., Matsuda, I., Akahane, M., Sato, J., Akai, H., Yasaka, K., Kunimatsu, A., & Ohtomo, K. (2012) · European Radiology · doi:10.1007/s00330-012-2452-z · Cited by 278
Metadata
- Authors
- Prakash, P., Kalra, M. K., Ackman, J. B., Digumarthy, S. R., Hsieh, J., Do, S., Shepard, J.-A. O., & Gilman, M. D.
- Venue
- Radiology
- Published
- 2010-07
- Volume
- 256
- Issue
- 1
- Pages
- 261-269
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137477427
- Cited by
- 162
- References
- 0
- FWCI
- 15.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique. https://app.cochat.ai/papers/10.1148/radiol.10091487
- The paper
- Prakash, P., Kalra, M. K., Ackman, J. B., Digumarthy, S. R., Hsieh, J., Do, S., Shepard, J.-A. O., & Gilman, M. D. (2010). Diffuse Lung Disease: CT of the Chest with Adaptive Statistical Iterative Reconstruction Technique. Radiology. https://doi.org/10.1148/radiol.10091487
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.