CoChat

Detection of Pancreatic Tumors, Image Quality, and Radiation Dose during the Pancreatic Parenchymal Phase: Effect of a Low-Tube-Voltage, High-Tube-Current CT Technique—Preliminary Results

Marin, Daniele, Nelson, Rendon C., Barnhart, Huiman, Schindera, Sebastian T., Ho, Lisa M., Jaffe, Tracy A., Yoshizumi, Terry T., Youngblood, Richard, Samei, Ehsan · 2010 · Radiology
Cited by 137

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase. MATERIALS AND METHODS: This prospective, single-center, HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Twenty-seven patients (nine men, 18 women; mean age, 64 years) with 23 solitary pancreatic tumors underwent dual-energy CT. Two imaging protocols were used: 140 kVp and 385 mA (protocol A) and 80 kVp and 675 mA (protocol B). For both protocols, the following variables were compared during the pancreatic parenchymal phase: contrast enhancement for the aorta, the pancreas, and the portal vein; pancreas-to-tumor contrast-to-noise ratio (CNR); noise; and effective dose. Two blinded, independent readers qualitatively scored the two data sets for tumor detection and image quality. Random-effect analysis of variance tests were used to compare differences between the two protocols. RESULTS: Compared with protocol A, protocol B yielded significantly higher contrast enhancement for the aorta (508.6 HU vs 221.5 HU, respectively), pancreas (151.2 HU vs 67.0 HU), and portal vein (189.7 HU vs 87.3 HU), along with a greater pancreas-to-tumor CNR (8.1 vs 5.9) (P < .001 for all comparisons). No statistically significant difference in tumor detection was observed between the two protocols. Although standard deviation of image noise increased with protocol B (11.5 HU vs 18.6 HU), this protocol significantly reduced the effective dose (from 18.5 to 5.1 mSv; P < .001). CONCLUSION: A low-tube-voltage, high-tube-current CT technique has the potential to improve the enhancement of the pancreas and peripancreatic vasculature, improve tumor conspicuity, and reduce patient radiation dose during the pancreatic parenchymal phase.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10091819

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Marin, D., Nelson, R. C., Barnhart, H., Schindera, S. T., Ho, L. M., Jaffe, T. A., Yoshizumi, T. T., Youngblood, R., & Samei, E.
Venue
Radiology
Published
2010-08
Volume
256
Issue
2
Pages
450-459
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2102147099
Cited by
137
References
4
FWCI
6.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.