Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 304

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Endovascular Treatment of Intracranial Unruptured Aneurysms: Systematic Review and Meta-Analysis of the Literature on Safety and Efficacy

Open access
Naggara, Olivier N., White, Phil M., Guilbert, François, Roy, Daniel, Weill, Alain, Raymond, Jean · 2010 · Radiology

Abstract

PURPOSE: To report an updated, systematic review of medical literature from January 2003 to July 2008, on endovascular treatment (EVT) of intracranial unruptured aneurysms (UAs) (a) to assess the morbidity and case fatality rate of EVT of UAs, (b) to understand how bias can affect results, and (c) to estimate the efficacy of EVT by using reported digital subtraction angiographic (DSA) results and clinical follow-up events. MATERIALS AND METHODS: This article was prepared in accordance with the Meta-Analysis of Observational Studies in Epidemiology and Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The literature was searched by using PubMed and the EMBASE and Cochrane Library databases. Eligibility criteria were (a) explicit procedural mortality and morbidity rates; (b) at least 10 patients; (c) saccular, intradural, nondissecting UAs; (d) original study published in English or French between January 2003 and July 2008; and (e) a methodological quality score higher than 6, according to Strengthening the Reporting of Observational Studies in Epidemiology criteria. End points included procedural mortality and morbidity, defined as a modified Rankin scale score of 3-6 at 1 month, and efficacy, estimated by using immediate and follow-up digital subtraction angiographic results, as well as delayed hemorrhagic events. RESULTS: Seventy-one studies were included. Procedural unfavorable outcome was found in 4.8% (random-effect weighted average; 189 of 5044) of patients (99% confidence interval [CI]: 3.9%, 6.0%). Immediate angiographic results showed satisfactory occlusion in 86.1% (2660 of 3089) of UAs. Recurrences were shown in 321 (24.4%) of 1316 patients followed up for 0.4-3.2 years. Retreatment was performed in 9.1% (random-effect weighted average; 166 of 1699) of patients (99% CI: 6.2%, 13.1%). The annual risk of bleeding after EVT was 0.2% (random-effect weighted average; nine of 1395) of patients (99% CI: 0.1%, 0.3%), but clinical follow-up was short, limited to the first 6 months for 76.7% (n = 1071) of reported patients. CONCLUSION: EVT of UAs can be performed with relative safety. The efficacy of treatment as compared with observation has not been rigorously documented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10091982

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 304

Metadata

Authors
Naggara, O. N., White, P. M., Guilbert, F., Roy, D., Weill, A., & Raymond, J.
Venue
Radiology
Published
2010-09
Volume
256
Issue
3
Pages
887-897
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2114873091
Cited by
304
References
37
FWCI
2.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endovascular Treatment of Intracranial Unruptured Aneurysms: Systematic Review and Meta-Analysis of the Literature on Safety and Efficacy. https://app.cochat.ai/papers/10.1148/radiol.10091982
The paper
Naggara, O. N., White, P. M., Guilbert, F., Roy, D., Weill, A., & Raymond, J. (2010). Endovascular Treatment of Intracranial Unruptured Aneurysms: Systematic Review and Meta-Analysis of the Literature on Safety and Efficacy. Radiology. https://doi.org/10.1148/radiol.10091982

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.