Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: To quantify contrast material enhancement of breast lesions scanned with dedicated breast computed tomography (CT) and to compare their conspicuity with that at unenhanced breast CT and mammography. MATERIALS AND METHODS: Approval of the institutional review board and the Radiation Use Committee and written informed consent were obtained for this HIPAA-compliant study. Between September 2006 and April 2009, 46 women (mean age, 53.2 years; age range, 35-72 years) with Breast Imaging Reporting and Data System category 4 or 5 lesions underwent unenhanced breast CT and contrast material-enhanced breast CT before biopsy. Two radiologists independently scored lesion conspicuity for contrast-enhanced breast CT versus mammography and for contrast-enhanced breast CT versus unenhanced breast CT. Mean lesion voxel intensity was measured in Hounsfield units and normalized to adipose tissue intensity on manually segmented images obtained before and after administration of contrast material. Regression models focused on conspicuity and quantified enhancement were used to estimate the effect of pathologic diagnosis (benign vs malignant), lesion type (mass vs calcifications), breast density, and interradiologist variability. RESULTS: Fifty-four lesions (25 benign, 29 malignant) in 46 subjects were analyzed. Malignant lesions were seen significantly better at contrast-enhanced breast CT than at unenhanced breast CT (P < .001) or mammography (P < .001). Malignant calcifications (malignant lesions manifested mammographically as microcalcifications only, n = 7) were seen better at contrast-enhanced breast CT than at unenhanced breast CT (P < .001) and were seen similarly at contrast-enhanced breast CT and mammography. Malignant lesions enhanced 55.9 HU +/- 4.0 (standard error), whereas benign lesions enhanced 17.6 HU +/- 6.1 (P < .001). Ductal carcinoma in situ (n = 5) enhanced a mean of 59.6 HU +/- 2.8. Receiver operating characteristic curve analysis of lesion enhancement yielded an area under the receiver operating characteristic curve of 0.876. CONCLUSION: Conspicuity of malignant breast lesions, including ductal carcinoma in situ, is significantly improved at contrast-enhanced breast CT. Quantifying lesion enhancement may aid in the detection and diagnosis of breast cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparison between Breast MRI and Contrast-Enhanced Spectral Mammography
Jakubowicz, J. (2015) · Medical Science Monitor · doi:10.12659/msm.893018 · Cited by 173
Hsu, J. C., Naha, P. C., Lau, K. C., Chhour, P., Hastings, R., Moon, B. F., Stein, J. M., Witschey, W. R. T., McDonald, E. S., Maidment, A. D. A., et al. (2018) · Nanoscale · doi:10.1039/c8nr03741h · Cited by 63
“These increases in tumor contrast post-injection are consistent with the in vivo DEM imaging results and indicate that AION have potential as contrast agents for breast cancer screening with CT, which could have use with future clinical breast CT scanners.(41-42) Page 14 of 40 Nanoscale”
Result
Metadata
- Authors
- Prionas, N. D., Lindfors, K. K., Ray, S., Huang, S.-Y., Beckett, L. A., Monsky, W. L., & Boone, J. M.
- Venue
- Radiology
- Published
- 2010-09
- Volume
- 256
- Issue
- 3
- Pages
- 714-723
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130582349
- Cited by
- 204
- References
- 0
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience. https://app.cochat.ai/papers/10.1148/radiol.10092311
- The paper
- Prionas, N. D., Lindfors, K. K., Ray, S., Huang, S.-Y., Beckett, L. A., Monsky, W. L., & Boone, J. M. (2010). Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience. Radiology. https://doi.org/10.1148/radiol.10092311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.