The DOI matches its Crossref record.
Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
Abstract
PURPOSE: To determine conversion factors for the new International Commission on Radiological Protection (ICRP) publication 103 recommendations for adult and pediatric patients and to compare the effective doses derived from Monte Carlo calculations with those derived from dose-length product (DLP) for different body regions and computed tomographic (CT) scanning protocols. MATERIALS AND METHODS: Effective dose values for the Oak Ridge National Laboratory phantom series, including phantoms for newborns; 1-, 5-, and 10-year-old children; and adults were determined by using Monte Carlo methods for a 64-section multidetector CT scanner. For each phantom, five anatomic regions (head, neck, chest, abdomen, and pelvis) were considered. Monte Carlo simulations were performed for spiral scanning protocols with different voltages. Effective dose was computed by using ICRP publication 60 and publication 103 recommendations. The calculated effective doses were compared with those derived from the DLP by using previously published conversion factors. RESULTS: In general, conversion factors determined on the basis of Monte Carlo calculations led to lower values for adults with both ICRP publications. Values up to 33% and 32% lower than previously published data were found for ICRP publication 60 and ICRP publication 103, respectively. For pediatric individuals, effective doses based on the Monte Carlo calculations were higher than those obtained from DLP and previously published conversion factors (eg, for chest CT scanning in 5-year-old children, an increase of about 76% would be expected). For children, a variation in conversion factors of up to 15% was observed when the tube voltage was varied. For adult individuals, no dependence on voltage was observed. CONCLUSION: Conversion factors from DLP to effective dose should be specified separately for both sexes and should reflect the new ICRP recommendations. For pediatric patients, new conversion factors specific for the spectrum used should be established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pickhardt, P. J., Lubner, M. G., Kim, D. H., Tang, J., Ruma, J. A., del Rio, A. M., & Chen, G.-H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9382 · Cited by 309
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
van Hamersvelt, R. W., Schilham, A. M. R., Engelke, K., den Harder, A. M., de Keizer, B., Verhaar, H. J., Leiner, T., de Jong, P. A., & Willemink, M. J. (2017) · European Radiology · doi:10.1007/s00330-017-4801-4 · Cited by 94
NATIONAL DIAGNOSTIC REFERENCE LEVEL INITIATIVE FOR COMPUTED TOMOGRAPHY EXAMINATIONS IN KENYA
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Boen, P. K. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv020 · Cited by 52
Metadata
- Authors
- Deak, P. D., Smal, Y., & Kalender, W. A.
- Venue
- Radiology
- Published
- 2010-10
- Volume
- 257
- Issue
- 1
- Pages
- 158-166
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2141834520
- Cited by
- 858
- References
- 0
- FWCI
- 26.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product. https://app.cochat.ai/papers/10.1148/radiol.10100047
- The paper
- Deak, P. D., Smal, Y., & Kalender, W. A. (2010). Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product. Radiology. https://doi.org/10.1148/radiol.10100047
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.