Evaluation of Clinical Breast MR Imaging Performed with Prototype Computer-aided Diagnosis Breast MR Imaging Workstation: Reader Study
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate a computer-aided diagnosis (CADx) system for dynamic contrast material-enhanced magnetic resonance (MR) imaging and compare it with a currently used clinical method of interpreting breast MR image findings that includes the use of commercially available automated software for kinetic image data processing and visualization. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, a training set of 121 breast lesions (77 malignant, 44 benign) was used to train the CADx system. After practicing with 10 training cases, six breast imaging radiologists assessed the likelihood of malignancy and the need for biopsy with a separate test set of 60 lesions (30 malignant, 30 benign). Their performances in differentiating between benign and malignant breast lesions both without (conventional lesion viewing, output from commercially available breast MR imaging analysis software) and with the aid of the CADx workstation (with classification yielding an estimation of the probability of malignancy for each lesion) were evaluated with receiver operating characteristic analysis. RESULTS: When CADx was used, the average performance of the radiologists was significantly improved, as indicated by increases in mean area under the receiver operating characteristic curve (from 0.80 to 0.84, P = .007), mean sensitivity (from 83% to 88%, P = .001), and average number of biopsy recommendations for malignant cases (1.7 more biopsies for malignant lesions with use of CADx, P = .032). Although the mean specificity improved (from 50% to 53%), the improvement was not significant (P = .2). CONCLUSION: Use of the CADx system improved the radiologists' performance in differentiating between malignant and benign MR imaging-depicted breast lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence in the interpretation of breast cancer on MRI
Sheth, D., & Giger, M. L. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26878 · Cited by 219
“…clinically translated such a system, which includes automatic lesion segmentation, feature extraction, and the merging of features into a tumor signature, and have demonstrated improvement in radiologist performance in the task of classifying between malignant and benign tumors 52 – 55, 81 ( Fig.”
BackgroundSelf-citationBreast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer
Giger, M. L., Karssemeijer, N., & Schnabel, J. A. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152416 · Cited by 206
Self-citationZhu, Y., Li, H., Guo, W., Drukker, K., Lan, L., Giger, M. L., & Ji, Y. (2015) · Scientific Reports · doi:10.1038/srep17787 · Cited by 165
Self-citationVasey, B., Ursprung, S., Beddoe, B., Taylor, E. H., Marlow, N., Bilbro, N., Watkinson, P., & McCulloch, P. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.1276 · Cited by 154
Guo, W., Li, H., Zhu, Y., Lan, L., Yang, S., Drukker, K., Morris, E. A., Burnside, E. S., Whitman, G. J., Giger, M. L., et al. (2015) · Journal of Medical Imaging · doi:10.1117/1.jmi.2.4.041007 · Cited by 148
Self-citation
Metadata
- Authors
- Shimauchi, A., Giger, M. L., Bhooshan, N., Lan, L., Pesce, L. L., Lee, J. K., Abe, H., & Newstead, G. M.
- Venue
- Radiology
- Published
- 2011-03
- Volume
- 258
- Issue
- 3
- Pages
- 696-704
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2140722149
- Cited by
- 41
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.