Characterization of Complex Adnexal Masses: Value of Adding Perfusion- and Diffusion-weighted MR Imaging to Conventional MR Imaging

Thomassin-Naggara, Isabelle, Toussaint, Irwin, Perrot, Nicolas, Rouzier, Roman, Cuenod, Charles A., Bazot, Marc, Daraï, Emile · 2011 · Radiology

Abstract

PURPOSE: To retrospectively determine the value of adding perfusion-weighted (PW) and diffusion-weighted (DW) sequences to a conventional magnetic resonance (MR) imaging protocol to differentiate benign from malignant tumors. MATERIALS AND METHODS: The institutional ethics committee approved this retrospective study and waived the requirement to obtain informed consent. MR images in 87 women (age range, 25-87 years) who underwent imaging before surgery for complex adnexal masses-excluding endometriomas and cystic teratomas-were analyzed. Conventional morphologic, perfusion, and diffusion MR criteria of malignancy were recorded. Three independent observers reviewed images in four steps: conventional MR images alone, conventional MR images and PW images combined, conventional MR images and DW images combined, and conventional, PW, and DW MR images combined. Receiver operating characteristic curve analysis was performed to compare the results of the readings. A recursive partitioning model was built to establish a multivariate decision tree. RESULTS: There was almost perfect agreement for lesion characterization regardless of the reader experiment or step considered (κ = 0.811-0.929). Area under the receiver operating characteristic curve values were higher for conventional and DW images combined, conventional and PW images combined, and conventional, DW, and PW images combined compared with conventional MR images alone (P < .05). For all readers, the accuracy of conventional, PW, and DW imaging combined was higher than that of conventional MR imaging alone for benign masses (P < .01) but not for malignant masses (P = .24). The addition of both PW and DW images led to a correct change in the diagnosis in 19% (11 of 57 patients), 23% (13 of 57 patients), and 24% (14 of 57 patients) of cases for readers 1, 2, and 3, respectively, with no incorrect changes. Conventional, PW, and DW MR imaging criteria were combined to generate a decision tree giving an accuracy of 95%. CONCLUSION: The addition of PW and DW sequences to a conventional MR imaging protocol improved the diagnostic accuracy in the characterization of complex adnexal masses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10100751

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Thomassin-Naggara, I., Toussaint, I., Perrot, N., Rouzier, R., Cuenod, C. A., Bazot, M., & Daraï, E.
Venue
Radiology
Published
2011-03
Volume
258
Issue
3
Pages
793-803
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2126364665
Cited by
195
References
2
FWCI
11.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of Complex Adnexal Masses: Value of Adding Perfusion- and Diffusion-weighted MR Imaging to Conventional MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.10100751
The paper
Thomassin-Naggara, I., Toussaint, I., Perrot, N., Rouzier, R., Cuenod, C. A., Bazot, M., & Daraï, E. (2011). Characterization of Complex Adnexal Masses: Value of Adding Perfusion- and Diffusion-weighted MR Imaging to Conventional MR Imaging. Radiology. https://doi.org/10.1148/radiol.10100751

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.