Computed Diffusion-weighted MR Imaging May Improve Tumor Detection
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To describe computed diffusion weighted (DW) magnetic resonance (MR) imaging as a method for obtaining high-b-value images from DW MR imaging performed at lower b values and to investigate the feasibility of the technique to improve lesion detection in oncologic cases. MATERIALS AND METHODS: The study was approved by the institutional and research committee, and written informed consent was obtained from all patients. DW MR imaging was performed on a CuSO(4) phantom at 1.5 T with a range of b values and compared with computed DW MR imaging images synthesized from lower b values (0 and 600 sec/mm(2)). The signal-to-noise ratio (SNR) was compared, and agreement between the SNR of computed DW MR imaging and theoretical estimation assessed. Computed DW MR imaging was evaluated in 10 oncologic patients who underwent whole-body DW MR imaging with b values of 0 and 900 sec/mm(2). Computed DW MR images at computed b values of 1500 and 2000 sec/mm(2) were generated. The image quality and background suppression of acquired and computed images were rated by a radiologist using a four-point scale. The diagnostic performance for malignant lesion detection using these images was evaluated and compared by using the McNemar Test. RESULTS: The SNR of computed DW MR imaging of the phantom conformed closely to theoretical predictions. Computed DW MR imaging resulted in a higher SNR compared with acquired DW MR imaging, especially at b values greater than 840 sec/mm(2). In patients, images with a computed b value of 2000 sec/mm(2) produced good image quality and high background suppression (mean scores of 2.8 and 4.0, respectively). Evaluation of images with a computed b value of 2000 sec/mm(2) resulted in higher overall diagnostic sensitivity (96.0%) and specificity (96.6%) compared with images with an acquired b value of 900 sec/mm(2) (sensitivity, 89.4%; specificity, 87.5%; P < .01). CONCLUSION: Computed DW MR imaging in the body allows higher-b-value images to be obtained with a good SNR. Clinical computed DW MR imaging is feasible and may improve disease detection. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101919/-/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Self-citationTakahara, T., Imai, Y., Yamashita, T., Yasuda, S., Nasu, S., & CAUTEREN, M. V. (2004) · PubMed · Cited by 781
Proceedings of the International Society for Magnetic Resonance in Medicine
(2018) · Proceedings of the Society of Magnetic Resonance in Medicine · doi:10.1002/(issn)1557-3672 · Cited by 718
Bennett, K. M., Schmainda, K. M., Bennett (Tong), R., Rowe, D. B., Lu, H., & Hyde, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10581 · Cited by 467
Practical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
KOH, D.-M., TAKAHARA, T., IMAI, Y., & COLLINS, D. J. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.211 · Cited by 211
Self-citationKingsley, P. B. (2006) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20050 · Cited by 150
Heusner, T.-A., Küemmel, S., Koeninger, A., Hamami, M., Hahn, S., Quinsten, A. S., Bockisch, A., Forsting, M., Lauenstein, T. C., Antoch, G., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1399-z · Cited by 143
Seo, H. S., Chang, K. H., Na, D. G., Kwon, B. J., & Lee, D. H. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0842 · Cited by 115
Kitajima, K., Kaji, Y., Kuroda, K., & Sugimura, K. (2008) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.7.93 · Cited by 104
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Molecular imaging for personalized cancer care
Kircher, M. F., Hricak, H., & Larson, S. M. (2012) · Molecular Oncology · doi:10.1016/j.molonc.2012.02.005 · Cited by 193
MAPS: A Quantitative Radiomics Approach for Prostate Cancer Detection
Cameron, A., Khalvati, F., Haider, M. A., & Wong, A. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2485779 · Cited by 185
“and the DWI-derived Apparent Diffusion Coefficient (ADC), which quantifies the diffusion of water molecules through tissue and has been shown to delineate between healthy and cancerous tissue [11], [12].”
BackgroundManganaro, L., Lakhman, Y., Bharwani, N., Gui, B., Gigli, S., Vinci, V., Rizzo, S., Kido, A., Cunha, T. M., Sala, E., et al. (2021) · European Radiology · doi:10.1007/s00330-020-07632-9 · Cited by 174
“Computed DWI-MR generated from the measured b values is a promising approach that maintains high signal-to-noise ratio and potentially improves tumour conspicuity, but the studies in cervical cancer are limited to date [11, 12].”
Background
Metadata
- Authors
- Blackledge, M. D., Leach, M. O., Collins, D. J., & Koh, D.-M.
- Venue
- Radiology
- Published
- 2011-11
- Volume
- 261
- Issue
- 2
- Pages
- 573-581
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137866361
- Cited by
- 172
- References
- 11
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computed Diffusion-weighted MR Imaging May Improve Tumor Detection. https://app.cochat.ai/papers/10.1148/radiol.11101919
- The paper
- Blackledge, M. D., Leach, M. O., Collins, D. J., & Koh, D.-M. (2011). Computed Diffusion-weighted MR Imaging May Improve Tumor Detection. Radiology. https://doi.org/10.1148/radiol.11101919
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.