Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 233

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial

Yuan, Ren, Shuman, William P., Earls, James P., Hague, Cameron J., Mumtaz, Hina A., Scott-Moncrieff, Andrew, Ellis, Jennifer D., Mayo, John R., Leipsic, Jonathon A. · 2012 · Radiology

Abstract

PURPOSE: To compare quantitative and subjective image quality and radiation dose between standard computed tomographic (CT) pulmonary angiography (CTPA) and CTPA with a dual-energy technique with reduced iodine load. MATERIALS AND METHODS: This prospective study was approved by the institutional review board and each participant provided informed consent. Ninety-four patients (59% male; mean age ± standard deviation, 62 years ± 15) were randomized to one of two protocols: standard CTPA (100-120 kVp) with standard contrast medium injection (n = 46) and dual-energy CTPA (image reconstruction at 50 keV) with the same injection volume as in the standard protocol but composed of contrast medium and saline in a 1:1 fashion, resulting in 50% reduction in iodine load (n = 48). Signal intensity and noise in three central and two segmental pulmonary arteries were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate vascular enhancement and image noise. The proportion of diagnostic (score, ≥ 3) studies and the interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale were compared between the two groups. RESULTS: Compared with standard CTPA, dual-energy CTPA demonstrated higher signal intensity in all pulmonary arteries (all P < .01), inferior noise only in segmental arteries (P < .05), higher SNR and CNR (both P < .05), and compatible effective dose (P > .05). The five-point score was higher in the standard CTPA protocol (P < .05). The interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale was similar (P > .05) between the two groups. CONCLUSION: Dual-energy CTPA with image reconstruction at 50 keV allows a significant reduction in iodine load while improving intravascular signal intensity, maintaining SNR and with comparable radiation dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11110648

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 233

Metadata

Authors
Yuan, R., Shuman, W. P., Earls, J. P., Hague, C. J., Mumtaz, H. A., Scott-Moncrieff, A., Ellis, J. D., Mayo, J. R., & Leipsic, J. A.
Venue
Radiology
Published
2012-01
Volume
262
Issue
1
Pages
290-297
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2139856958
Cited by
233
References
1
FWCI
9.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial. https://app.cochat.ai/papers/10.1148/radiol.11110648
The paper
Yuan, R., Shuman, W. P., Earls, J. P., Hague, C. J., Mumtaz, H. A., Scott-Moncrieff, A., Ellis, J. D., Mayo, J. R., & Leipsic, J. A. (2012). Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial. Radiology. https://doi.org/10.1148/radiol.11110648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.