The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial
Abstract
PURPOSE: To compare quantitative and subjective image quality and radiation dose between standard computed tomographic (CT) pulmonary angiography (CTPA) and CTPA with a dual-energy technique with reduced iodine load. MATERIALS AND METHODS: This prospective study was approved by the institutional review board and each participant provided informed consent. Ninety-four patients (59% male; mean age ± standard deviation, 62 years ± 15) were randomized to one of two protocols: standard CTPA (100-120 kVp) with standard contrast medium injection (n = 46) and dual-energy CTPA (image reconstruction at 50 keV) with the same injection volume as in the standard protocol but composed of contrast medium and saline in a 1:1 fashion, resulting in 50% reduction in iodine load (n = 48). Signal intensity and noise in three central and two segmental pulmonary arteries were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate vascular enhancement and image noise. The proportion of diagnostic (score, ≥ 3) studies and the interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale were compared between the two groups. RESULTS: Compared with standard CTPA, dual-energy CTPA demonstrated higher signal intensity in all pulmonary arteries (all P < .01), inferior noise only in segmental arteries (P < .05), higher SNR and CNR (both P < .05), and compatible effective dose (P > .05). The five-point score was higher in the standard CTPA protocol (P < .05). The interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale was similar (P > .05) between the two groups. CONCLUSION: Dual-energy CTPA with image reconstruction at 50 keV allows a significant reduction in iodine load while improving intravascular signal intensity, maintaining SNR and with comparable radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A solution to the problem of separation in logistic regression
Heinze, G., & Schemper, M. (2002) · Statistics in Medicine · doi:10.1002/sim.1047 · Cited by 2,711
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
State of the Art: Iterative CT Reconstruction Techniques
Geyer, L. L., Schoepf, U. J., Meinel, F. G., Nance, J. W., Bastarrika, G., Leipsic, J. A., Paul, N. S., Rengo, M., Laghi, A., & De Cecco, C. N. (2015) · Radiology · doi:10.1148/radiol.2015132766 · Cited by 704
Self-citationAchenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J. K., & Leipsic, J. A. (2012) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2012.11.002 · Cited by 634
Self-citation
Metadata
- Authors
- Yuan, R., Shuman, W. P., Earls, J. P., Hague, C. J., Mumtaz, H. A., Scott-Moncrieff, A., Ellis, J. D., Mayo, J. R., & Leipsic, J. A.
- Venue
- Radiology
- Published
- 2012-01
- Volume
- 262
- Issue
- 1
- Pages
- 290-297
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2139856958
- Cited by
- 233
- References
- 1
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial. https://app.cochat.ai/papers/10.1148/radiol.11110648
- The paper
- Yuan, R., Shuman, W. P., Earls, J. P., Hague, C. J., Mumtaz, H. A., Scott-Moncrieff, A., Ellis, J. D., Mayo, J. R., & Leipsic, J. A. (2012). Reduced Iodine Load at CT Pulmonary Angiography with Dual-Energy Monochromatic Imaging: Comparison with Standard CT Pulmonary Angiography—A Prospective Randomized Trial. Radiology. https://doi.org/10.1148/radiol.11110648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.