CoChat

Articular Cartilage: In Vivo Diffusion-Tensor Imaging

Raya, José G., Horng, Annie, Dietrich, Olaf, Krasnokutsky, Svetlana, Beltran, Luis S., Storey, Pippa, Reiser, Maximilian F., Recht, Michael P., K. Sodickson, Daniel, Glaser, Christian · 2012 · Radiology
Cited by 108

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate technical feasibility, test-retest reproducibility, and the ability to differentiate healthy subjects from subjects with osteoarthritis (OA) with diffusion-tensor (DT) imaging parameters and T2 relaxation time. MATERIALS AND METHODS: This study was approved by the institutional review board and was HIPAA compliant. All subjects provided written informed consent. DT imaging parameters and T2 (resolution=0.6×0.6×2 mm) of patellar cartilage were measured at 7.0 T in 16 healthy volunteers and 10 patients with OA with subtle inhomogeneous signal intensity but no signs of cartilage erosion at clinical magnetic resonance (MR) imaging. Ten volunteers were imaged twice to determine test-retest reproducibility. After cartilage segmentation, maps of mean apparent diffusion coefficient (ADC), fractional anisotropy (FA), and T2 relaxation time were calculated. Differences for ADC, FA, and T2 between the healthy and OA populations were assessed with nonparametric tests. The ability of each MR imaging parameter to help discriminate healthy subjects from subjects with OA was assessed by using receiver operating characteristic curve analysis. RESULTS: Test-retest reproducibility was better than 10% for mean ADC (8.1%), FA (9.7%), and T2 (5.9%). Mean ADC and FA differed significantly (P<.01) between the OA and healthy populations, but T2 did not. For ADC, the optimal threshold to differentiate both populations was 1.2×10(-3) mm2/sec, achieving specificity of 1.0 (16 of 16) and sensitivity of 0.80 (eight of 10). For FA, the optimal threshold was 0.25, yielding specificity of 0.88 (14 of 16) and sensitivity of 0.80 (eight of 10). T2 showed poor differentiation between groups (optimal threshold=22.9 msec, specificity=0.69 [11 of 16], sensitivity=0.60 [six of 10]). CONCLUSION: In vivo DT imaging of patellar cartilage is feasible, has good test-retest reproducibility, and may be accurate in discriminating healthy subjects from subjects with OA. ADC and FA are two promising biomarkers for early OA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.11110821

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 108

Metadata

Authors
Raya, J. G., Horng, A., Dietrich, O., Krasnokutsky, S., Beltran, L. S., Storey, P., Reiser, M. F., Recht, M. P., K. Sodickson, D., & Glaser, C.
Venue
Radiology
Published
2012-02
Volume
262
Issue
2
Pages
550-559
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2166134413
Cited by
108
References
4
FWCI
5.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Articular Cartilage: In Vivo Diffusion-Tensor Imaging. https://app.cochat.ai/papers/10.1148/radiol.11110821
The paper
Raya, J. G., Horng, A., Dietrich, O., Krasnokutsky, S., Beltran, L. S., Storey, P., Reiser, M. F., Recht, M. P., K. Sodickson, D., & Glaser, C. (2012). Articular Cartilage: In Vivo Diffusion-Tensor Imaging. Radiology. https://doi.org/10.1148/radiol.11110821

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.