MR Imaging of the Small Bowel
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Small-bowel radiology has undergone dramatic changes in the past 2 decades. Despite important recent advances in small-bowel endoscopy, radiologic imaging remains important for patients suspected of having or with established small-bowel disease. Cross-sectional imaging techniques (computed tomography and magnetic resonance [MR] imaging), used to investigate both extraluminal abnormalities and intraluminal changes, have gradually replaced barium contrast examinations, which are, however, still used to examine early mucosal disease. MR imaging techniques clearly highlight endoluminal, mural and extramural enteric details and provide vascular and functional information, thereby enhancing the diagnostic value of these techniques in small-bowel diseases. Two MR imaging based techniques are currently utilized: MR enteroclysis and MR enterography. In enteroclysis, enteric contrast material is administered through a nasoenteric tube, whereas in enterography, large volumes of enteric contrast material are administered orally. MR enteroclysis ensures consistently better luminal distention than does MR enterography in both the jejunum and the ileum and more accurately depicts endoluminal abnormalities and early disease, particularly at the level of the jejunal loops. Moreover, MR enteroclysis provides a high level of accuracy in the diagnosis and exclusion of small-bowel inflammatory and neoplastic diseases and can be used for the first radiologic evaluation, while MR enterography may effectively be used to follow up both Crohn disease patients without jejunal disease and in pediatric patients where nasogastric intubation might be a problem. MR enteroclysis may also reveal subtle transition points or an obstruction in the lower small bowel, which may escape detection when more routine methods, including enterography, are used. MR imaging offers detailed morphologic information and functional data of small-bowel diseases and provides reliable evidence of normalcy, thereby allowing the diagnosis of early or subtle structural abnormalities and guiding treatment and decisions in patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SIMPLE INDEX OF CROHN'S-DISEASE ACTIVITY
Harvey, R. F., & Bradshaw, J. M. (1980) · The Lancet · doi:10.1016/s0140-6736(80)92767-1 · Cited by 2,959
Green, P. H. R., & Cellier, C. (2007) · New England Journal of Medicine · doi:10.1056/nejmra071600 · Cited by 1,625
Costamagna, G., Shah, S. K., Riccioni, M. E., Foschia, F., Mutignani, M., Perri, V., Vecchioli, A., Brizi, M. G., Picciocchi, A., & Marano, P. (2002) · Gastroenterology · doi:10.1053/gast.2002.35988 · Cited by 796
Magnetic resonance for assessment of disease activity and severity in ileocolonic Crohn’s disease
Rimola, J., Rodriguez, S., García-Bosch, O., Ordás, I., Ayala, E., Aceituno, M., Pellisé, M., Ayuso, C., Ricart, E., Donoso, L., et al. (2009) · Gut · doi:10.1136/gut.2008.167957 · Cited by 675
Goldstein, J. L., Eisen, G. M., Lewis, B., Gralnek, I. M., Zlotnick, S., & Fort, J. G. (2005) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00619-6 · Cited by 659
Horsthuis, K., Bipat, S., Bennink, R. J., & Stoker, J. (2008) · Radiology · doi:10.1148/radiol.2471070611 · Cited by 634
Siddiki, H. A., Fidler, J. L., Fletcher, J. G., Burton, S. S., Huprich, J. E., Hough, D. M., Johnson, C. D., Bruining, D. H., Loftus, E. V., Sandborn, W. J., et al. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2027 · Cited by 389
MR Imaging Evaluation of the Activity of Crohn's Disease
Koh, D. M., Miao, Y., Chinn, R. J. S., Amin, Z., Zeegen, R., Westaby, D., & Healy, J. C. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771325 · Cited by 358
Role of US in Detection of Crohn Disease: Meta-Analysis
Fraquelli, M., Colli, A., Casazza, G., Paggi, S., Colucci, A., Massironi, S., Duca, P., & Conte, D. (2005) · Radiology · doi:10.1148/radiol.2361040799 · Cited by 307
Albert, J., Martiny, F., Krummenerl, A., Stock, K., Leßke, J., Göbel, C. M., Lotterer, E., Nietsch, H. H., Behrmann, C., & Fleig, W. E. (2005) · Gut · doi:10.1136/gut.2005.069427 · Cited by 303
Cited by
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Organ-specific toxicity of magnetic iron oxide-based nanoparticles
Chrishtop, V. V., Mironov, V. A., Prilepskii, A. Y., Nikonorova, V. G., & Vinogradov, V. V. (2021) · Nanotoxicology · doi:10.1080/17435390.2020.1842934 · Cited by 86
Metadata
- Authors
- Masselli, G., & Gualdi, G.
- Venue
- Radiology
- Published
- 2012-08
- Volume
- 264
- Issue
- 2
- Pages
- 333-348
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2120653934
- Cited by
- 188
- References
- 39
- FWCI
- 13.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.