Reduction of Metal Artifacts in Patients with Total Hip Arthroplasty with Slice-encoding Metal Artifact Correction and View-Angle Tilting MR Imaging
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the new "warp" sequence (slice-encoding metal artifact correction [SEMAC], view-angle tilting [VAT], and increased bandwidth) for the reduction of both through-plane and in-plane magnetic resonance (MR) artifacts with current optimized MR sequences in patients with total hip arthroplasty (THA). MATERIALS AND METHODS: The institutional review board issued a waiver for this study. Forty patients with THA were prospectively included. SEMAC, VAT, and increased bandwidth were applied by using the warp turbo-spin-echo sequence at 1.5 T. Coronal short tau inversion-recovery (STIR)-warp and transverse T1-weighted warp (hereafter, T1-warp) images, as well as standard coronal STIR and transverse T1-weighted sequence images optimized with high bandwidth (STIR-hiBW and T1-hiBW), were acquired. Fifteen additional patients were examined to compare the T1-warp and T1-hiBW sequence with an identical matrix size. Signal void was quantified. Qualitative criteria (distinction of anatomic structures, blurring, and noise) were assessed on a five-point scale (1, no artifacts; 5, not visible due to severe artifacts) by two readers. Abnormal imaging findings were recorded. Quantitative data were analyzed with a t test and qualitative data with a Wilcoxon signed rank test. RESULTS: Signal void around the acetabular component was smaller for STIR-warp than STIR-hiBW images (21.6 cm2 vs 42.4 cm2; P=.0001), and for T1-warp than T1-hiBW images (17.6 cm2 vs 20.2 cm2; P=.0001). Anatomic distinction was better on STIR-warp compared with STIR-hiBW images (1.9-2.8 vs 3.6-4.6; P=.0001), and on T1-warp compared with T1-hiBW images (1.3-2.8 vs 1.8-3.2; P<.002). Distortion, blurring, and noise were lower with warp sequences than with the standard sequences (P=.0001). Almost half of the abnormal imaging findings were missed on STIR-hiBW compared with STIR-warp images (55 vs 105 findings; P=.0001), while T1-hiBW was similar to T1-warp imaging (50 vs 55 findings; P=.06). CONCLUSION: STIR-warp and T1-warp sequences were significantly better according to quantitative and qualitative image criteria, but a clinically relevant artifact reduction was only present for STIR images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529786 · Cited by 4,332
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Cited by
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Jungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25708 · Cited by 227
“It was demonstrated in several studies that SEMAC is superior to standard MR sequences, high bandwidth protocols, and simple VAT with respect to artifact reduction.(1,2,84,85)”
Self-citationRapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Metadata
- Authors
- Sutter, R., Ulbrich, E. J., Jellus, V., Nittka, M., & Pfirrmann, C. W. A.
- Venue
- Radiology
- Published
- 2012-10
- Volume
- 265
- Issue
- 1
- Pages
- 204-214
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2141701272
- Cited by
- 161
- References
- 2
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduction of Metal Artifacts in Patients with Total Hip Arthroplasty with Slice-encoding Metal Artifact Correction and View-Angle Tilting MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.12112408
- The paper
- Sutter, R., Ulbrich, E. J., Jellus, V., Nittka, M., & Pfirrmann, C. W. A. (2012). Reduction of Metal Artifacts in Patients with Total Hip Arthroplasty with Slice-encoding Metal Artifact Correction and View-Angle Tilting MR Imaging. Radiology. https://doi.org/10.1148/radiol.12112408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.