Interobserver Variability in the CT Assessment of Honeycombing in the Lungs

Watadani, Takeyuki, Sakai, Fumikazu, Johkoh, Takeshi, Noma, Satoshi, Akira, Masanori, Fujimoto, Kiminori, Bankier, Alexander A., Lee, Kyung Soo, Müller, Nestor L., Song, Jae-Woo, Park, Jai-Soung, Lynch, David A., Hansell, David M., Remy-Jardin, Martine, Franquet, Tomás, Sugiyama, Yukihiko·2013·Radiology

Abstract

PURPOSE: To quantify observer agreement and analyze causes of disagreement in identifying honeycombing at chest computed tomography (CT). MATERIALS AND METHODS: The institutional review board approved this multiinstitutional HIPAA-compliant retrospective study, and informed patient consent was not required. Five core study members scored 80 CT images with a five-point scale (5 = definitely yes to 1 = definitely no) to establish a reference standard for the identification of honeycombing. Forty-three observers from various subspecialties and geographic regions scored the CT images by using the same scoring system. Weighted κ values of honeycombing scores compared with the reference standard were analyzed to investigate intergroup differences. Images were divided into four groups to allow analysis of imaging features of cases in which there was disagreement: agreement on the presence of honeycombing, agreement on the absence of honeycombing, disagreement on the presence of honeycombing, and other (none of the preceding three groups applied). RESULTS: Agreement of scores of honeycombing presence by 43 observers with the reference standard was moderate (Cohen weighted κ values: 0.40-0.58). There were no significant differences in κ values among groups defined by either subspecialty or geographic region (Tukey-Kramer test, P = .38 to >.99). In 29% of cases, there was disagreement on identification of honeycombing. These cases included honeycombing mixed with traction bronchiectasis, large cysts, and superimposed pulmonary emphysema. CONCLUSION: Identification of honeycombing at CT is subjective, and disagreement is largely caused by conditions that mimic honeycombing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12112516

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 411

Metadata

Authors
Watadani, T., Sakai, F., Johkoh, T., Noma, S., Akira, M., Fujimoto, K., Bankier, A. A., Lee, K. S., Müller, N. L., Song, J.-W., Park, J.-S., Lynch, D. A., Hansell, D. M., Remy-Jardin, M., Franquet, T., & Sugiyama, Y.
Venue
Radiology
Published
2013-03
Volume
266
Issue
3
Pages
936-944
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2135761719
Cited by
411
References
27
FWCI
14.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interobserver Variability in the CT Assessment of Honeycombing in the Lungs. https://app.cochat.ai/papers/10.1148/radiol.12112516
The paper
Watadani, T., Sakai, F., Johkoh, T., Noma, S., Akira, M., Fujimoto, K., Bankier, A. A., Lee, K. S., Müller, N. L., Song, J.-W., Park, J.-S., Lynch, D. A., Hansell, D. M., Remy-Jardin, M., Franquet, T., & Sugiyama, Y. (2013). Interobserver Variability in the CT Assessment of Honeycombing in the Lungs. Radiology. https://doi.org/10.1148/radiol.12112516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.