The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation
Abstract
PURPOSE: To compare five methodologies the American Association of Physicists in Medicine Report 204 used to calculate size-specific dose estimates (SSDEs) for pediatric computed tomography (CT). MATERIALS AND METHODS: The institutional review board waived consent for this HIPAA-compliant retrospective study. The five SSDE methodologies were investigated for calculation variation based on volumetric CT dose index (CTDI), or CTDI(vol), of chest, abdominal, and pelvic CT. SSDE calculations were derived from a predominantly pediatric population of 186 patients retrospectively and consecutively analyzed from June through November 2011. Eighty (43%) of the 186 patients were female, and 106 (57%) were male. Mean patient age was 8.6 years ± 6.3 (standard deviation), the age range was 1 month to 28 years, and mean weight was 37.7 kg ± 33.1, with a range of 3.4-146.6 kg. SSDE conversion factors were derived from anteroposterior (AP) and lateral dimensions measured on the patient's CT radiograph. The measurements were either used independently, or as a summation, or to calculate the patient's effective diameter; additionally, SSDE was derived on the basis of the patient's age (International Commission on Radiation Units Report 74 data). SSDE conversion factors were applied to CTDI(vol) data that corrected for both 16- and 32-cm-diameter CTDI phantom measurements. SSDE data were summarized by using the patient's originally prescribed weight-based CT scanning protocols. Data were summarized by using descriptive statistics. RESULTS: SSDEs derived from individual measurements varied 2%-12%. The combination of measurements (sum or effective diameter) varied 0.9%-2%. The age approach varied by an average of 2% (in the younger population [0-13 years]), but up to 44%, with an average of 18% (in the older population [14-18 years]). No SSDE correction was required for patients of varying size who weighed 36 kg or less when CTDI(vol) was measured by using a 16-cm CTDI phantom or for patients weighing 100-140 kg when CTDI(vol) was measured by using a 32-cm phantom. CTDI(vol) measured by using a 32-cm phantom in patients weighing between 36 and 100 kg and patients weighing more than 140 kg differed from SSDE by an average of 35%. An average difference of 1% was found between male and female SSDE-corrected values when the two sexes were compared within the same CT weight scanning categories. CONCLUSION: The combination of AP and lateral measurements should be used to determine SSDE correction factors when possible. For pediatric patients, CTDI(vol) calculated with a 32-cm phantom requires SSDE conversion to more accurately estimate patient dose; CTDI(vol) calculated with a 16-cm phantom for pediatric patients weighing 36 kg or less does not require SSDE conversion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“SSDE, originally introduced by the American Association of Physicists in Medicine (AAPM Report No. 204),92 is increasingly utilized in pediatric imaging and adult body CT, where patient size markedly influences radiation absorption.”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [92]
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
NCRP report no. 93: Ionizing radiation exposure of the population of the United States
Eckelman, W. C. (1988) · International Journal of Radiation Applications and Instrumentation Part B Nuclear Medicine and Biology · doi:10.1016/0883-2897(88)90020-7 · Cited by 755
CT Dose Index and Patient Dose: They AreNotthe Same Thing
McCollough, C. H., Leng, S., Yu, L., CODY, D. D., Boone, J. M., & McNitt‐Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Boone, J. M. (2007) · Medical Physics · doi:10.1118/1.2713240 · Cited by 418
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 381
Patient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. Z. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?
Huda, W., & Mettler, F. A. (2010) · Radiology · doi:10.1148/radiol.10100297 · Cited by 209
Suzuki, A., & Suzuki, M. N. (1978) · Medical Physics · doi:10.1118/1.594445 · Cited by 66
Research works printed but not linked: 3
- Boone J, 2011, Report of AAPM Task Group 204
- Report Committee, 2005, J ICRU, 5
- GE Healthcare, 2010, Lightspeed VCT
Cited by
Sorted by citations
Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT
Akagi, M., Nakamura, Y., Higaki, T., Narita, K., Honda, Y., Zhou, J., Yu, Z., Akino, N., & Awai, K. (2019) · European Radiology · doi:10.1007/s00330-019-06170-3 · Cited by 347
CT Radiation: Key Concepts for Gentle and Wise Use
Kalra, M. K., Sodickson, A. D., & Mayo-Smith, W. W. (2015) · Radiographics · doi:10.1148/rg.2015150118 · Cited by 122
Moore, B. M., Brady, S. L., Mirro, A. E., & Kaufman, R. A. (2014) · Medical Physics · doi:10.1118/1.4884227 · Cited by 112
Self-citationArtificial intelligence in image reconstruction: The change is here
Singh, R., Wu, W., Wang, G., & Kalra, M. K. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.11.012 · Cited by 116
Smith, E. A., Dillman, J. R., Goodsitt, M. M., Christodoulou, E., Keshavarzi, N., & Strouse, P. J. (2013) · Radiology · doi:10.1148/radiol.13130362 · Cited by 105
Metadata
- Authors
- Brady, S. L., & Kaufman, R. A.
- Affiliations
- St. Jude Children's Research Hospital (US)
- Venue
- Radiology
- Published
- 2012-12
- Volume
- 265
- Issue
- 3
- Pages
- 832-840
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2108902262
- Cited by
- 137
- References
- 9
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 5 · 2023: 8 · 2022: 9 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 12 · 2017: 12 · 2016: 13 · 2015: 15 · 2014: 19 · 2013: 11 · 2012: 2
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Keywords
- size-specific dose estimate, pediatric computed tomography, volumetric CT dose index, conversion factors, patient size, effective diameter, radiation dose reduction, pediatric radiation protection
- MeSH terms
- Adolescent, Adult, Body Weight, Child, Child, Preschool, Female, Humans, Infant, Male, Pediatrics, Radiation Dosage, Radiometry, Retrospective Studies, Risk, Societies, Medical, Tomography, X-Ray Computed, United States, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation. https://app.cochat.ai/papers/10.1148/radiol.12120131
- The paper
- Brady, S. L., & Kaufman, R. A. (2012). Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation. Radiology. https://doi.org/10.1148/radiol.12120131