Cited by 137Radiation Dose and ImagingAdvanced Radiotherapy TechniquesDigital Radiography and Breast Imaging

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation

Abstract

PURPOSE: To compare five methodologies the American Association of Physicists in Medicine Report 204 used to calculate size-specific dose estimates (SSDEs) for pediatric computed tomography (CT). MATERIALS AND METHODS: The institutional review board waived consent for this HIPAA-compliant retrospective study. The five SSDE methodologies were investigated for calculation variation based on volumetric CT dose index (CTDI), or CTDI(vol), of chest, abdominal, and pelvic CT. SSDE calculations were derived from a predominantly pediatric population of 186 patients retrospectively and consecutively analyzed from June through November 2011. Eighty (43%) of the 186 patients were female, and 106 (57%) were male. Mean patient age was 8.6 years ± 6.3 (standard deviation), the age range was 1 month to 28 years, and mean weight was 37.7 kg ± 33.1, with a range of 3.4-146.6 kg. SSDE conversion factors were derived from anteroposterior (AP) and lateral dimensions measured on the patient's CT radiograph. The measurements were either used independently, or as a summation, or to calculate the patient's effective diameter; additionally, SSDE was derived on the basis of the patient's age (International Commission on Radiation Units Report 74 data). SSDE conversion factors were applied to CTDI(vol) data that corrected for both 16- and 32-cm-diameter CTDI phantom measurements. SSDE data were summarized by using the patient's originally prescribed weight-based CT scanning protocols. Data were summarized by using descriptive statistics. RESULTS: SSDEs derived from individual measurements varied 2%-12%. The combination of measurements (sum or effective diameter) varied 0.9%-2%. The age approach varied by an average of 2% (in the younger population [0-13 years]), but up to 44%, with an average of 18% (in the older population [14-18 years]). No SSDE correction was required for patients of varying size who weighed 36 kg or less when CTDI(vol) was measured by using a 16-cm CTDI phantom or for patients weighing 100-140 kg when CTDI(vol) was measured by using a 32-cm phantom. CTDI(vol) measured by using a 32-cm phantom in patients weighing between 36 and 100 kg and patients weighing more than 140 kg differed from SSDE by an average of 35%. An average difference of 1% was found between male and female SSDE-corrected values when the two sexes were compared within the same CT weight scanning categories. CONCLUSION: The combination of AP and lateral measurements should be used to determine SSDE correction factors when possible. For pediatric patients, CTDI(vol) calculated with a 32-cm phantom requires SSDE conversion to more accurately estimate patient dose; CTDI(vol) calculated with a 16-cm phantom for pediatric patients weighing 36 kg or less does not require SSDE conversion.

Overview

Integrity signals

Registry

Crossref · 10.1148/radiol.12120131

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 9 references

Research works printed but not linked: 3

  1. Boone J, 2011, Report of AAPM Task Group 204
  2. Report Committee, 2005, J ICRU, 5
  3. GE Healthcare, 2010, Lightspeed VCT

Cited by

Sorted by citations

Items 101–137 of 137

Metadata

Authors
Brady, S. L., & Kaufman, R. A.
Affiliations
St. Jude Children's Research Hospital (US)
Venue
Radiology
Published
2012-12
Volume
265
Issue
3
Pages
832-840
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2108902262
Cited by
137
References
9
Citations by year
2026: 7 · 2025: 4 · 2024: 5 · 2023: 8 · 2022: 9 · 2021: 9 · 2020: 6 · 2019: 5 · 2018: 12 · 2017: 12 · 2016: 13 · 2015: 15 · 2014: 19 · 2013: 11 · 2012: 2
FWCI
11.35
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
Keywords
size-specific dose estimate, pediatric computed tomography, volumetric CT dose index, conversion factors, patient size, effective diameter, radiation dose reduction, pediatric radiation protection
MeSH terms
Adolescent, Adult, Body Weight, Child, Child, Preschool, Female, Humans, Infant, Male, Pediatrics, Radiation Dosage, Radiometry, Retrospective Studies, Risk, Societies, Medical, Tomography, X-Ray Computed, United States, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review