Computer-aided Detection of Masses at Mammography: Interactive Decision Support versus Prompts
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare effectiveness of an interactive computer-aided detection (CAD) system, in which CAD marks and their associated suspiciousness scores remain hidden unless their location is queried by the reader, with the effect of traditional CAD prompts used in current clinical practice for the detection of malignant masses on full-field digital mammograms. MATERIALS AND METHODS: The requirement for institutional review board approval was waived for this retrospective observer study. Nine certified screening radiologists and three residents who were trained in breast imaging read 200 studies (63 studies containing at least one screen-detected mass, 17 false-negative studies, 20 false-positive studies, and 100 normal studies) twice, once with CAD prompts and once with interactive CAD. Localized findings were reported and scored by the readers. In the prompted mode, findings were recorded before and after activation of CAD. The partial area under the location receiver operating characteristic (ROC) curve for an interval of low false-positive fractions typical for screening, from 0 to 0.2, was computed for each reader and each mode. Differences in reader performance were analyzed by using software. RESULTS: The average partial area under the location ROC curve with unaided reading was 0.57, and it increased to 0.62 with interactive CAD, while it remained unaffected by prompts. The difference in reader performance for unaided reading versus interactive CAD was statistically significant (P = .009). CONCLUSION: When used as decision support, interactive use of CAD for malignant masses on mammograms may be more effective than the current use of CAD, which is aimed at the prevention of perceptual oversights.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
“In parallel, it could also be used as an interactive decision support tool (27), pointing out potential lesions and preventing overlook and interpretation errors that are relatively common in the reading of DM (6–9).”
BackgroundSelf-citationDetection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Self-citationGeras, K. J., Mann, R. M., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182627 · Cited by 295
Self-citationArtificial intelligence in breast imaging
Le, E. P. V., Wang, Y., Huang, Y., Hickman, S., & Gilbert, F. J. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.02.006 · Cited by 276
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Teuwen, J., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Mertelmeier, T., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06186-9 · Cited by 210
Self-citation
Metadata
- Authors
- Hupse, R., Samulski, M., Lobbes, M. B., Mann, R. M., Mus, R., den Heeten, G. J., Beijerinck, D., Pijnappel, R. M., Boetes, C., & Karssemeijer, N.
- Venue
- Radiology
- Published
- 2013-01
- Volume
- 266
- Issue
- 1
- Pages
- 123-129
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130635849
- Cited by
- 60
- References
- 0
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer-aided Detection of Masses at Mammography: Interactive Decision Support versus Prompts. https://app.cochat.ai/papers/10.1148/radiol.12120218
- The paper
- Hupse, R., Samulski, M., Lobbes, M. B., Mann, R. M., Mus, R., den Heeten, G. J., Beijerinck, D., Pijnappel, R. M., Boetes, C., & Karssemeijer, N. (2013). Computer-aided Detection of Masses at Mammography: Interactive Decision Support versus Prompts. Radiology. https://doi.org/10.1148/radiol.12120218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.