The DOI matches its Crossref record.
Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR Imaging
Abstract
PURPOSE: To retrospectively compare transition zone (TZ) cancer detection and localization accuracy of 3-T T2-weighted magnetic resonance (MR) imaging with that of multiparametric (MP) MR imaging, with radical prostatectomy specimens as the reference standard. MATERIALS AND METHODS: The informed consent requirement was waived by the institutional review board. Inclusion criteria were radical prostatectomy specimen TZ cancer larger than 0.5 cm(3) and 3-T endorectal presurgery MP MR imaging (T2-weighted imaging, diffusion-weighted [DW] imaging apparent diffusion coefficient [ADC] maps [b < 1000 sec/mm(2)], and dynamic contrast material-enhanced [DCE] MR imaging). From 197 patients with radical prostatectomy specimens, 28 patients with TZ cancer were included. Thirty-five patients without TZ cancer were randomly selected as a control group. Four radiologists randomly scored T2-weighted and DW ADC images, T2-weighted and DCE MR images, and T2-weighted, DW ADC, and DCE MR images. TZ cancer suspicion was rated on a five-point scale in six TZ regions of interest (ROIs). A score of 4-5 was considered a positive finding. A score of 4 or higher for any ROI containing TZ cancer was considered a positive detection result at the patient level. Generalized estimating equations were used to analyze detection and localization accuracy by using ROI-receiver operating characteristics (ROC) curve analyses for the latter. Gleason grade (GG) 4-5 and GG 2-3 cancers were analyzed separately. RESULTS: Detection accuracy did not differ between T2-weighted and MP MR imaging for all TZ cancers (68% vs 66%, P = .85), GG 4-5 TZ cancers (79% vs 72%-75%, P = .13), and GG 2-3 TZ cancers (66% vs 62%-65%, P = .47). MP MR imaging (area under the ROC curve, 0.70-0.77) did not improve T2-weighted imaging localization accuracy (AUC = 0.72) (P > .05). CONCLUSION: Use of 3-T MP MR imaging, consisting of T2-weighted imaging, DW imaging ADC maps (b values, 50, 500, and 800 sec/mm(2)), and DCE MR imaging may not improve TZ cancer detection and localization accuracy compared with T2-weighted imaging. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120281/-/DC1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of prostate segmentation algorithms for mri: The promise12 challenge
Litjens, G., Toth, R., van de Ven, W., Hoeks, C., Kerkstra, S., van Ginneken, B., Vincent, G., Guillard, G., Birbeck, N., Zhang, J., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.12.002 · Cited by 857
Self-citationCurrent use of PSMA–PET in prostate cancer management
Maurer, T., Eiber, M., Schwaiger, M., & Gschwend, J. E. (2016) · Nature Reviews Urology · doi:10.1038/nrurol.2016.26 · Cited by 611
Simultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate Cancer
Eiber, M., Weirich, G., Holzapfel, K., Souvatzoglou, M., Haller, B., Rauscher, I., Beer, A. J., Wester, H.-J., Gschwend, J., Schwaiger, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.12.053 · Cited by 568
Rosenkrantz, A. B., Kim, S., Lim, R. P., Hindman, N., Deng, F.-M., Babb, J. S., & Taneja, S. S. (2013) · Radiology · doi:10.1148/radiol.13122233 · Cited by 267
Metadata
- Authors
- Hoeks, C. M. A., Hambrock, T., Yakar, D., Hulsbergen–van de Kaa, C. A., Feuth, T., Witjes, J. A., Fütterer, J. J., & Barentsz, J. O.
- Venue
- Radiology
- Published
- 2013-01
- Volume
- 266
- Issue
- 1
- Pages
- 207-217
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2134850935
- Cited by
- 235
- References
- 0
- FWCI
- 18.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.12120281
- The paper
- Hoeks, C. M. A., Hambrock, T., Yakar, D., Hulsbergen–van de Kaa, C. A., Feuth, T., Witjes, J. A., Fütterer, J. J., & Barentsz, J. O. (2013). Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR Imaging. Radiology. https://doi.org/10.1148/radiol.12120281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.