Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 258

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Methods for Calculating Sensitivity and Specificity of Clustered Data: A Tutorial

Open access
Genders, Tessa S. S., Spronk, Sandra, Stijnen, Theo, Steyerberg, Ewout W., Lesaffre, Emmanuel, Hunink, M. G. Myriam · 2012 · Radiology

Abstract

UNLABELLED: The performance of a diagnostic test is often expressed in terms of sensitivity and specificity compared with the reference standard. Calculations of sensitivity and specificity commonly involve multiple observations per patient, which implies that the data are clustered. Whether analysis of sensitivity and specificity per patient or using multiple observations per patient is preferable depends on the clinical context and consequences. The purpose of this article was to discuss and illustrate the most common statistical methods that calculate sensitivity and specificity of clustered data, adjusting for the possible correlation between observations within each patient. This tutorial presents and illustrates the following methods: (a) analysis at different levels ignoring correlation, (b) variance adjustment, (c) logistic random-effects models, and (d) generalized estimating equations. The choice of method and the level of reporting should correspond with the clinical decision problem. If multiple observations per patient are relevant to the clinical decision problem, the potential correlation between observations should be explored and taken into account in the statistical analysis. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120509/-/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120509

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 258

Metadata

Authors
Genders, T. S. S., Spronk, S., Stijnen, T., Steyerberg, E. W., Lesaffre, E., & Hunink, M. G. M.
Venue
Radiology
Published
2012-12
Volume
265
Issue
3
Pages
910-916
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2125444765
Cited by
258
References
15
FWCI
7.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Methods for Calculating Sensitivity and Specificity of Clustered Data: A Tutorial. https://app.cochat.ai/papers/10.1148/radiol.12120509
The paper
Genders, T. S. S., Spronk, S., Stijnen, T., Steyerberg, E. W., Lesaffre, E., & Hunink, M. G. M. (2012). Methods for Calculating Sensitivity and Specificity of Clustered Data: A Tutorial. Radiology. https://doi.org/10.1148/radiol.12120509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.