The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Diagnostic Accuracy of a Machine-Learning Approach to Coronary Computed Tomographic Angiography–Based Fractional Flow Reserve: Result From the MACHINE Consortium
Open accessAbstract
Background: Coronary computed tomographic angiography (CTA) is a reliable modality to detect coronary artery disease. However, CTA generally overestimates stenosis severity compared with invasive angiography, and angiographic stenosis does not necessarily imply hemodynamic relevance when fractional flow reserve (FFR) is used as reference. CTA-based FFR (CT-FFR), using computational fluid dynamics (CFD), improves the correlation with invasive FFR results but is computationally demanding. More recently, a new machine-learning (ML) CT-FFR algorithm has been developed based on a deep learning model, which can be performed on a regular workstation. In this large multicenter cohort, the diagnostic performance ML-based CT-FFR was compared with CTA and CFD-based CT-FFR for detection of functionally obstructive coronary artery disease. Methods and Results: At 5 centers in Europe, Asia, and the United States, 351 patients, including 525 vessels with invasive FFR comparison, were included. ML-based and CFD-based CT-FFR were performed on the CTA data, and diagnostic performance was evaluated using invasive FFR as reference. Correlation between ML-based and CFD-based CT-FFR was excellent ( R =0.997). ML-based (area under curve, 0.84) and CFD-based CT-FFR (0.84) outperformed visual CTA (0.69; P <0.0001). On a per-vessel basis, diagnostic accuracy improved from 58% (95% confidence interval, 54%–63%) by CTA to 78% (75%–82%) by ML-based CT-FFR. The per-patient accuracy improved from 71% (66%–76%) by CTA to 85% (81%–89%) by adding ML-based CT-FFR as 62 of 85 (73%) false-positive CTA results could be correctly reclassified by adding ML-based CT-FFR. Conclusions: On-site CT-FFR based on ML improves the performance of CTA by correctly reclassifying hemodynamically nonsignificant stenosis and performs equally well as CFD-based CT-FFR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Predicting the future - big data, machine learning, and clinical medicine
Obermeyer, Z., & Emanuel, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmp1606181 · Cited by 3,652
Fractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary Disease
De Bruyne, B., Pijls, N. H. J., Kalesan, B., Barbato, E., Tonino, P. A. L., Piroth, Z., Jagic, N., Möbius-Winkler, S., Rioufol, G., Witt, N., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1205361 · Cited by 2,772
Budoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Nørgaard, B. L., Leipsic, J., Gaur, S., Seneviratne, S., Ko, B. S., Ito, H., Jensen, J. M., Mauri, L., De Bruyne, B., Bezerra, H., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.043 · Cited by 1,498
Koo, B.-K., Erglis, A., Doh, J.-H., Daniels, D. V., Jegere, S., Kim, H.-S., Dunning, A., DeFrance, T., Lansky, A., Leipsic, J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.066 · Cited by 1,282
Angiographic Versus Functional Severity of Coronary Artery Stenoses in the FAME Study
Tonino, P. A. L., Fearon, W. F., De Bruyne, B., Oldroyd, K. G., Leesar, M. A., Ver Lee, P. N., MacCarthy, P. A., van't Veer, M., & Pijls, N. H. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.096 · Cited by 1,271
Cited by
Evaluation of artificial intelligence techniques in disease diagnosis and prediction
Ghaffar Nia, N., Kaplanoglu, E., & Nasab, A. (2023) · Discover Artificial Intelligence · doi:10.1007/s44163-023-00049-5 · Cited by 426
Narula, J., Chandrashekhar, Y., Ahmadi, A., Abbara, S., Berman, D. S., Blankstein, R., Leipsic, J., Newby, D., Nicol, E. D., Nieman, K., et al. (2021) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.11.001 · Cited by 398
Self-citationAdvancements in AI based healthcare techniques with FOCUS ON diagnostic techniques
Kalra, N., Verma, P., & Verma, S. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108917 · Cited by 95
Artificial Intelligence in Cardiovascular Medicine
Seetharam, K., Shrestha, S., & Sengupta, P. P. (2019) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-019-0728-1 · Cited by 76
Mastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Metadata
- Authors
- Coenen, A., Kim, Y.-H., Kruk, M., Tesche, C., De Geer, J., Kurata, A., Lubbers, M. L., Daemen, J., Itu, L., Rapaka, S., Sharma, P., Schwemmer, C., Persson, A., Schoepf, U. J., Kepka, C., Hyun Yang, D., & Nieman, K.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2018-06
- Volume
- 11
- Issue
- 6
- Pages
- e007217-e007217
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2807965844
- Cited by
- 397
- References
- 42
- FWCI
- 24.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Accuracy of a Machine-Learning Approach to Coronary Computed Tomographic Angiography–Based Fractional Flow Reserve: Result From the MACHINE Consortium. https://app.cochat.ai/papers/10.1161/circimaging.117.007217
- The paper
- Coenen, A., Kim, Y.-H., Kruk, M., Tesche, C., De Geer, J., Kurata, A., Lubbers, M. L., Daemen, J., Itu, L., Rapaka, S., Sharma, P., Schwemmer, C., Persson, A., Schoepf, U. J., Kepka, C., Hyun Yang, D., & Nieman, K. (2018). Diagnostic Accuracy of a Machine-Learning Approach to Coronary Computed Tomographic Angiography–Based Fractional Flow Reserve: Result From the MACHINE Consortium. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.117.007217
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.