Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Perfusion CT in Acute Stroke: A Comprehensive Analysis of Infarct and Penumbra

Bivard, Andrew, Levi, Christopher, Spratt, Neil, Parsons, Mark·2013·Radiology

Abstract

PURPOSE: To perform a large-scale systematic comparison of the accuracy of all commonly used perfusion computed tomography (CT) data postprocessing methods in the definition of infarct core and penumbra in acute stroke. MATERIALS AND METHODS: The collection of data for this study was approved by the institutional ethics committee, and all patients gave informed consent. Three hundred fourteen patients with hemispheric ischemia underwent perfusion CT within 6 hours of stroke symptom onset and magnetic resonance (MR) imaging at 24 hours. CT perfusion maps were generated by using six different postprocessing methods. Pixel-based analysis was used to calculate sensitivity and specificity of different perfusion CT thresholds for the penumbra and infarct core with each postprocessing method, and receiver operator characteristic (ROC) curves were plotted. Area under the ROC curve (AUC) analysis was used to define the optimum threshold. RESULTS: Delay-corrected singular value deconvolution (SVD) with a delay time of more than 2 seconds most accurately defined the penumbra (AUC = 0.86, P = .046, mean volume difference between acute perfusion CT and 24-hour diffusion-weighted MR imaging = 1.7 mL). A double core threshold with a delay time of more than 2 seconds and cerebral blood flow less than 40% provided the most accurate definition of the infarct core (AUC = 0.86, P = .038). The other SVD measures (block circulant, nondelay corrected) were more accurate than non-SVD methods. CONCLUSION: This study has shown that there is marked variability in penumbra and infarct prediction among various deconvolution techniques and highlights the need for standardization of perfusion CT in stroke. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120971/-/DC1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120971

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 265

Metadata

Authors
Bivard, A., Levi, C., Spratt, N., & Parsons, M.
Venue
Radiology
Published
2013-05
Volume
267
Issue
2
Pages
543-550
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2152705022
Cited by
265
References
13
FWCI
11.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perfusion CT in Acute Stroke: A Comprehensive Analysis of Infarct and Penumbra. https://app.cochat.ai/papers/10.1148/radiol.12120971
The paper
Bivard, A., Levi, C., Spratt, N., & Parsons, M. (2013). Perfusion CT in Acute Stroke: A Comprehensive Analysis of Infarct and Penumbra. Radiology. https://doi.org/10.1148/radiol.12120971

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.