The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High Sensitivity of Diffusion-weighted MR Imaging for the Detection of Liver Metastases from Neuroendocrine Tumors: Comparison with T2-weighted and Dynamic Gadolinium-enhanced MR Imaging
Abstract
PURPOSE: To compare the sensitivity and specificity of diffusion-weighted (DW) magnetic resonance (MR) imaging for identifying liver metastases from neuroendocrine tumor (NET) to those of T2-weighted fast spin-echo (FSE) and three-dimensional dynamic gadolinium-enhanced MR imaging, with surgical and histopathologic findings as the reference standard. MATERIALS AND METHODS: This retrospective study was approved by institutional review board, and informed consent was waived. Fifty-nine patients with NETs (41 patients with 162 liver metastases, and 18 control subjects with no liver metastases) underwent MR imaging that included DW, T2-weighted FSE, and dynamic gadolinium-enhanced MR sequences. Images were retrospectively reviewed by two abdominal radiologists, independently, for the detection and characterization of liver metastases. MR findings were compared with histopathologic and intraoperative ultrasonography findings for metastasis on a lesion-by-lesion basis to determine the sensitivity of each MR sequence alone and combined. Specificity was calculated by using the control population. Interreader agreement for each MR sequence and McNemar test were also calculated. RESULTS: There was excellent agreement between observers 1 and 2 for characterizing liver metastases at per-lesion analysis (κ coefficient: 0.86-1.00). DW MR was more sensitive (observer 1: sensitivity, 71.6% [116 of 162], 95% confidence interval [CI]: 64.2%, 78.0%; observer 2: sensitivity, 71.0% [115 of 162], 95% CI: 63.6%, 77.4%) than T2-weighted FSE (observer 1: sensitivity, 55.6% [90 of 162], 95% CI: 47.9%, 63.0%; observer 2: sensitivity, 55.6% [90 of 162], 95% CI: 47.9%, 63.0%) and dynamic gadolinium-enhanced MR (observer 1: sensitivity, 47.5% [77 of 162], 95% CI: 34.0%, 55.2%; observer 2: sensitivity, 48.1% [78 of 162], 95% CI: 40.6%, 55.8%) (P < .001 for both, McNemar test). The specificity of these sequences ranged from 88.9% to 100% (DW MR vs T2-weighted FSE MR: P > .99, DW MR vs dynamic gadolinium-enhanced MR: P = .61, and T2-weighted FSE MR vs dynamic gadolinium-enhanced MR: P = .61, McNemar test). CONCLUSION: DW MR imaging was more sensitive for the detection and characterization of liver metastases from NETs than T2-weighted FSE and dynamic gadolinium-enhanced MR imaging and should be systematically performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/33156643 · Cited by 149
Cited by
Recommendations for management of patients with neuroendocrine liver metastases
Frilling, A., Modlin, I. M., Kidd, M., Russell, C., Breitenstein, S., Salem, R., Kwekkeboom, D., Lau, W.-Y., Klersy, C., Vilgrain, V., et al. (2014) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70362-0 · Cited by 527
Self-citationHofland, J., Falconi, M., Christ, E., Castaño, J. P., Faggiano, A., Lamarca, A., Perren, A., Petrucci, S., Prasad, V., Ruszniewski, P., et al. (2023) · Journal of Neuroendocrinology · doi:10.1111/jne.13318 · Cited by 259
Self-citation
Metadata
- Authors
- d’Assignies, G., Fina, P., Bruno, O., Vullierme, M.-P., Tubach, F., Paradis, V., Sauvanet, A., Ruszniewski, P., & Vilgrain, V.
- Venue
- Radiology
- Published
- 2013-08
- Volume
- 268
- Issue
- 2
- Pages
- 390-399
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2097562338
- Cited by
- 212
- References
- 2
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Sensitivity of Diffusion-weighted MR Imaging for the Detection of Liver Metastases from Neuroendocrine Tumors: Comparison with T2-weighted and Dynamic Gadolinium-enhanced MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.13121628
- The paper
- d’Assignies, G., Fina, P., Bruno, O., Vullierme, M.-P., Tubach, F., Paradis, V., Sauvanet, A., Ruszniewski, P., & Vilgrain, V. (2013). High Sensitivity of Diffusion-weighted MR Imaging for the Detection of Liver Metastases from Neuroendocrine Tumors: Comparison with T2-weighted and Dynamic Gadolinium-enhanced MR Imaging. Radiology. https://doi.org/10.1148/radiol.13121628
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.