The DOI matches its Crossref record; 18 of the 20 references it cites were found in a registry or an index.
Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2weighted turbo spin echo techniques
Abstract
The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b = 0, b = 20, b = 300, b = 800 s mm(-2)) and single-shot T2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with special interest in small (<10 mm) lesions. Twenty-four patients underwent routine MRI. The five sequences were compared qualitatively for image quality, lesion conspicuity and artefacts. Quantitative analysis was performed for lesion identification and lesion-to-liver contrast-to-noise ratio (CNR). Subgroup analyses were performed for different types of lesions with different sizes. Sequences were compared by rank order statistic (RIDIT) and Kruskal-Wallis test. The best image quality (p<0.05) was achieved with T2W TSE and the best lesion conspicuity (p<0.05) with T2W TSE for biliary cysts and SE-EPI diffusion-weighted imaging (DWI) (b = 20 s mm(-2)) for haemangiomas and metastases. Image artefacts were lowest (p<0.05) with T2W TSE. T2W TSE was found to be the best protocol (p<0.05) for the identification of biliary cysts and SE-EPI DWI (b = 20 s mm(-2)) for haemangiomas and metastases. The lesion-to-liver CNRs were highest on T2W TSE for biliary cysts and on SE-EPI diffusion-weighted imaging (DWI) for haemangiomas and metastases (p<0.05). This study shows the potential of SS SE-EPI DWI (especially with a b-value of 20 s mm(-2)) as a promising technique for detecting small (<10 mm) focal liver lesions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Diffusion-weighted imaging may help to distinguish well-differentiated hepatocellular carcinomas from benign nodules [17,18], C Dionisi Vici and L Monti unpublished.”
From Recommendations for the management of tyrosinaemia type 1 (2013) · cites this paper as [17]
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Bross, I. D. J. (1958) · Biometrics · doi:10.2307/2527727 · Cited by 635
Farzaneh, F., Riederer, S. J., & Pelc, N. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140112 · Cited by 362
Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.2.9456953 · Cited by 314
Taouli, B. A., Martin, A. J., Qayyum, A., Merriman, R. B., Vigneron, D. B., Yeh, B. M., & Coakley, F. V. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.3.1830677 · Cited by 134
Goldberg, M. A., Hahn, P. F., Saini, S., Cohen, M. S., Reimer, P., Brady, T. J., & Mueller, P. R. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.5.8470568 · Cited by 95
T2-weighted MR Imaging in the Assessment of Cirrhotic Liver
Hussain, H. K., Syed, I. I., Nghiem, H. V., Johnson, T. D., Carlos, R. C., Weadock, W. J., & Francis, I. R. (2004) · Radiology · doi:10.1148/radiol.2303020921 · Cited by 91
Echo-planar imaging of the liver with a standard MR imaging system.
Butts, K., Riederer, S. J., Ehman, R. L., Felmlee, J. P., & Grimm, R. C. (1993) · Radiology · doi:10.1148/radiology.189.1.8396785 · Cited by 89
Okada, Y., Ohtomo, K., Kiryu, S., & Sasaki, Y. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199805000-00005 · Cited by 85
Hussain, S. M., Becker, J. D., Hop, W. C. J., Dwarkasing, S., & Wielopolski, P. A. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20269 · Cited by 82
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Recommendations for the management of tyrosinaemia type 1
de Laet, C., Dionisi-Vici, C., Leonard, J. V., McKiernan, P., Mitchell, G., Monti, L., de Baulny, H. O., Pintos-Morell, G., & Spiekerkötter, U. (2013) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-8-8 · Cited by 227
d’Assignies, G., Fina, P., Bruno, O., Vullierme, M.-P., Tubach, F., Paradis, V., Sauvanet, A., Ruszniewski, P., & Vilgrain, V. (2013) · Radiology · doi:10.1148/radiol.13121628 · Cited by 212
Diffusion-weighted MR Imaging of the Pancreas: Current Status and Recommendations
Barral, M., Taouli, B., Guiu, B., Koh, D.-M., Luciani, A., Manfredi, R., Vilgrain, V., Hoeffel, C., Kanematsu, M., & Soyer, P. (2015) · Radiology · doi:10.1148/radiol.14130778 · Cited by 208
Utility of diffusion‐weighted MRI in distinguishing benign and malignant hepatic lesions
Miller, F. H., Hammond, N., Siddiqi, A. J., Shroff, S., Khatri, G., Wang, Y., Merrick, L. B., & Nikolaidis, P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22235 · Cited by 188
Metadata
- Authors
- Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J.
- Affiliations
- Amsterdam UMC Location University of Amsterdam (NL)
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-07
- Volume
- 80
- Issue
- 955
- Pages
- 524-531
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1966369454
- Cited by
- 149
- References
- 20
- Citations by year
- 2026: 4 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 5 · 2017: 5 · 2016: 8 · 2015: 9 · 2014: 10 · 2013: 18 · 2012: 20
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Radiology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Keywords
- focal liver lesions, diffusion-weighted imaging, fast spin echo, T2-weighted imaging, small liver lesions, b-value, lesion conspicuity, contrast-to-noise ratio, biliary cysts, hepatic hemangioma, liver metastasis, image artifacts
- MeSH terms
- Aged, Bile Duct Diseases, Cysts, Female, Hemangioma, Humans, Image Interpretation, Computer-Assisted, Liver, Liver Diseases, Liver Neoplasms, Male, Middle Aged, Probability, Statistics as Topic, Artifacts, Echo-Planar Imaging, Diffusion Magnetic Resonance Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2weighted turbo spin echo techniques. https://app.cochat.ai/papers/10.1259/bjr/33156643
- The paper
- Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007). Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2weighted turbo spin echo techniques. The British Journal of Radiology. https://doi.org/10.1259/bjr/33156643
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.