Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record.

Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT

Wang, Chien-Kuo, Tsai, Jen-Ming, Chuang, Ming-Tsung, Wang, Min-Tsung, Huang, Kuo-Yuan, Lin, Ruey-Mo · 2013 · Radiology

Abstract

PURPOSE: To assess the use of the dual-energy computed tomographic (CT) virtual noncalcium technique in the evaluation of bone marrow edema in vertebral compression fractures. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; informed consent was obtained from all patients. Sixty-three consecutive patients with 112 thoracic and/or lumbar vertebral compression fractures were studied between January 2011 and April 2012. All patients underwent both dual-energy CT (100 kV and Sn140 kV, where Sn indicates the use of a 0.4-mm tin filter) and magnetic resonance (MR) imaging. Dual-energy CT data were postprocessed by using a three-material decomposition algorithm for generating noncalcium images of the collapsed bodies. Two radiologists evaluated for the presence of abnormal attenuation alterations in the bone marrow by using color-coded maps and measured CT numbers on noncalcium grayscale images. Bone sclerosis and intravertebral air were evaluated with CT scans. MR images served as the reference standard. CT numbers were subjected to receiver operating characteristic curve analysis. RESULTS: MR imaging depicted 46 edematous and 66 nonedematous vertebral compression fractures. Eighty-two bodies were classified as having less than 50% sclerosis and/or air. Significant differences in noncalcium CT numbers between edematous and nonedematous vertebral compression fractures were found for both readers (P < .0001). CT numbers for the diagnosis of bone marrow edema on the basis of MR imaging revealed areas under the receiver operating characteristic curve of 0.799 and 0.841 for readers 1 and 2, respectively (P = .56). Use of a cutoff value of -80 to differentiate edematous vertebral bodies resulted in a sensitivity of 96.3%, specificity of 98.2%, and accuracy of 97.6% in the group of vertebral bodies with less than 50% sclerosis and/or air. CONCLUSION: Dual-energy CT virtual noncalcium images were able to depict bone marrow in the collapsed vertebral bodies, especially in those with less than 50% sclerosis and/or air.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.13122577

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Wang, C.-K., Tsai, J.-M., Chuang, M.-T., Wang, M.-T., Huang, K.-Y., & Lin, R.-M.
Venue
Radiology
Published
2013-11
Volume
269
Issue
2
Pages
525-533
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2104806088
Cited by
177
References
0
FWCI
9.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT. https://app.cochat.ai/papers/10.1148/radiol.13122577
The paper
Wang, C.-K., Tsai, J.-M., Chuang, M.-T., Wang, M.-T., Huang, K.-Y., & Lin, R.-M. (2013). Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT. Radiology. https://doi.org/10.1148/radiol.13122577

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.