C-Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients

Lee, Sang Min, Park, Chang Min, Lee, Kyung Hee, Bahn, Young Eun, Kim, Jung Im, Goo, Jin Mo · 2014 · Radiology

Abstract

PURPOSE: To retrospectively evaluate the diagnostic performance and complications of C-arm cone-beam computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) in 1108 patients. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board with waiver of patient informed consent. From January 2009 to December 2011, 1108 patients (633 male, 475 female; mean age, 62.4 years ± 12.3 [standard deviation]) with 1116 pulmonary lesions (mean size, 2.7 cm ± 1.7) underwent 1153 cone-beam CT-guided PTNBs. A coaxial system with 18-gauge cutting needles was used. Diagnostic performance, complication rate, influencing factors, and patient radiation exposure were investigated. Variables influencing diagnostic performance and complications were assessed by using uni- and multivariate logistic regression analyses. RESULTS: Among 1153 PTNBs, pathologic analysis showed 1148 (99.6%) were technically successful (766 malignant [66.4%], 323 benign [28.0%], and 59 [5.1%] indeterminate). Sensitivity, specificity, and accuracy for diagnosis of malignancy were 95.7% (733 of 766), 100% (323 of 323), and 97.0% (1056 of 1089), respectively. In regard to diagnostic failures (five technical failures, 33 false-negative findings), lesions 1 cm in diameter or smaller and lesions in the lower lobe were significant risk factors (P = .028 and P = .034, respectively). As for complications, pneumothorax and hemoptysis occurred in 196 (17.0%) and 80 (6.9%) procedures, respectively. Multivariate analysis revealed two or more pleural passages and emphysema along the needle pathway were the two most significant risk factors for pneumothorax, and ground-glass nodules were the most significant risk factor for hemoptysis (P < .001 for all). Virtual guidance was a significant protective factor for both pneumothorax and hemoptysis (P < .001 for both). Mean estimated effective radiation dose through cone-beam CT-guided PTNBs was 7.3 mSv ± 4.1. CONCLUSION: Cone-beam CT-guided PTNB is a highly accurate and safe technique with which to diagnose pulmonary lesions with reasonable radiation exposure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.13131265

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 207

Metadata

Authors
Lee, S. M., Park, C. M., Lee, K. H., Bahn, Y. E., Kim, J. I., & Goo, J. M.
Venue
Radiology
Published
2014-04
Volume
271
Issue
1
Pages
291-300
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2145790229
Cited by
207
References
1
FWCI
7.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: C-Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients. https://app.cochat.ai/papers/10.1148/radiol.13131265
The paper
Lee, S. M., Park, C. M., Lee, K. H., Bahn, Y. E., Kim, J. I., & Goo, J. M. (2014). C-Arm Cone-Beam CT-guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules: Clinical Experience in 1108 Patients. Radiology. https://doi.org/10.1148/radiol.13131265

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.