CoChat

Computer-aided Detection Improves Detection of Pulmonary Nodules in Chest Radiographs beyond the Support by Bone-suppressed Images

Open access
Schalekamp, Steven, van Ginneken, Bram, Koedam, Emmeline, Snoeren, Miranda M., Tiehuis, Audrey M., Wittenberg, Rianne, Karssemeijer, Nico, Schaefer-Prokop, Cornelia M. · 2014 · Radiology
Cited by 80

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the added value of computer-aided detection (CAD) for lung nodules on chest radiographs when radiologists have bone-suppressed images (BSIs) available. MATERIALS AND METHODS: Written informed consent was waived by the institutional review board. Selection of study images and study setup was reviewed and approved by the institutional review boards. Three hundred posteroanterior (PA) and lateral chest radiographs (189 radiographs with negative findings and 111 radiographs with a solitary nodule) in 300 subjects were selected from image archives at four institutions. PA images were processed by using a commercially available CAD, and PA BSIs were generated. Five radiologists and three residents evaluated the radiographs with BSIs available, first, without CAD and, second, after inspection of the CAD marks. Readers marked locations suspicious for a nodule and provided a confidence score for that location to be a nodule. Location-based receiver operating characteristic analysis was performed by using jackknife alternative free-response receiver operating characteristic analysis. Area under the curve (AUC) functioned as figure of merit, and P values were computed with the Dorfman-Berbaum-Metz method. RESULTS: Average nodule size was 16.2 mm. Stand-alone CAD reached a sensitivity of 74% at 1.0 false-positive mark per image. Without CAD, average AUC for observers was 0.812. With CAD, performance significantly improved to an AUC of 0.841 (P = .0001). CAD detected 127 of 239 nodules that were missed after evaluation of the radiographs together with BSIs pooled over all observers. Only 57 of these detections were eventually marked by the observers after review of CAD candidates. CONCLUSION: CAD improved radiologists' performance for the detection of lung nodules on chest radiographs, even when baseline performance was optimized by providing lateral radiographs and BSIs. Still, most of the true-positive CAD candidates are dismissed by observers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14131315

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 80

Metadata

Authors
Schalekamp, S., van Ginneken, B., Koedam, E., Snoeren, M. M., Tiehuis, A. M., Wittenberg, R., Karssemeijer, N., & Schaefer-Prokop, C. M.
Venue
Radiology
Published
2014-07
Volume
272
Issue
1
Pages
252-261
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2100791815
Cited by
80
References
1
FWCI
2.91
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.