Repeatability of Metabolically Active Tumor Volume Measurements with FDG PET/CT in Advanced Gastrointestinal Malignancies: A Multicenter Study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the feasibility and repeatability of various metabolically active tumor volume ( MATV metabolically active tumor volume ) quantification methods in fluorine 18 fluorodeoxyglucose ( FDG fluorine 18 fluorodeoxyglucose ) positron emission tomography (PET)/computed tomography (CT) in a multicenter setting and propose the optimal MATV metabolically active tumor volume method together with the minimal threshold for future response evaluation studies. MATERIALS AND METHODS: The study was approved by the institutional review board of all four participating centers, and patients provided written informed consent. Thirty-four patients with advanced gastrointestinal malignancies underwent two FDG fluorine 18 fluorodeoxyglucose PET/CT examinations within 1 week. MATV metabolically active tumor volume s were defined semiautomatically with 27 variations of tumor delineation methods with different reference values. Feasibility was determined as the percentage of successful tumor segmentations per MATV metabolically active tumor volume method. Repeatability was determined with intraclass correlation coefficients, Bland-Altman plots, and limits of agreement ( LOA limit of agreement s) of the percentage difference between the test and repeat test measurements. In addition, LOA limit of agreement variability per center was investigated. RESULTS: In total, 136 lesions were identified. Feasibility of tumor segmentation ranged from 54% to 100% (74-136 of 136 lesions); repeatability was evaluated for 19 MATV metabolically active tumor volume methods with feasibility of greater than 95%. The median MATV metabolically active tumor volume derived with 50% threshold of mean standardized uptake value ( SUV standardized uptake value ) of a sphere of 12-mm diameter with highest local intensity ( SUVhp mean SUV of a sphere of 12-mm diameter with highest local intensity ), which may not include the voxel with highest SUV standardized uptake value corrected for local background, was 5.7 and 6.1 mL for test and retest scans, respectively, with a relative LOA limit of agreement of 36.1%. Comparable repeatability was found between centers. A difference in uptake time between scan 1 and 2 of 15 minutes or longer had a minor negative influence on repeatability. CONCLUSION: MATV metabolically active tumor volume measured with 50% of SUVhp mean SUV of a sphere of 12-mm diameter with highest local intensity corrected for local background is recommended in multicenter FDG fluorine 18 fluorodeoxyglucose PET/CT studies on the basis of a high feasibility (96%) and repeatability ( LOA limit of agreement of 36.1%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationFDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
“Other tumour segmentation methods have been described for MTVassessment and/or tumour delineation for radiotherapy planning in the literature, such as contrast-oriented methods [48, 83–85], gradient-based methods [86], iterative methods [87] and fuzzy clustering/segmentation methods [88].”
Self-citationBensch, F., van der Veen, E. L., Lub-de Hooge, M. N., Jorritsma-Smit, A., Boellaard, R., Kok, I. C., Oosting, S. F., Schröder, C. P., Hiltermann, T. J. N., van der Wekken, A. J., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0255-8 · Cited by 732
Self-citationvan Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Self-citationFeasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Self-citation
Metadata
- Authors
- Frings, V., van Velden, F. H. P., Velasquez, L. M., Hayes, W., van de Ven, P. M., Hoekstra, O. S., & Boellaard, R.
- Venue
- Radiology
- Published
- 2014-11
- Volume
- 273
- Issue
- 2
- Pages
- 539-548
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2101910303
- Cited by
- 103
- References
- 2
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.