Characterizing Search, Recognition, and Decision in the Detection of Lung Nodules on CT Scans: Elucidation with Eye Tracking
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine the effectiveness of radiologists' search, recognition, and acceptance of lung nodules on computed tomographic (CT) images by using eye tracking. MATERIALS AND METHODS: This study was performed with a protocol approved by the institutional review board. All study subjects provided informed consent, and all private health information was protected in accordance with HIPAA. A remote eye tracker was used to record time-varying gaze paths while 13 radiologists interpreted 40 lung CT images with an average of 3.9 synthetic nodules (5-mm diameter) embedded randomly in the lung parenchyma. The radiologists' gaze volumes ( GV gaze volume s) were defined as the portion of the lung parenchyma within 50 pixels (approximately 3 cm) of all gaze points. The fraction of the total lung volume encompassed within the GV gaze volume s, the fraction of lung nodules encompassed within each GV gaze volume (search effectiveness), the fraction of lung nodules within the GV gaze volume detected by the reader (recognition-acceptance effectiveness), and overall sensitivity of lung nodule detection were measured. RESULTS: Detected nodules were within 50 pixels of the nearest gaze point for 990 of 992 correct detections. On average, radiologists searched 26.7% of the lung parenchyma in 3 minutes and 16 seconds and encompassed between 86 and 143 of 157 nodules within their GV gaze volume s. Once encompassed within their GV gaze volume , the average sensitivity of nodule recognition and acceptance ranged from 47 of 100 nodules to 103 of 124 nodules (sensitivity, 0.47-0.82). Overall sensitivity ranged from 47 to 114 of 157 nodules (sensitivity, 0.30-0.73) and showed moderate correlation (r = 0.62, P = .02) with the fraction of lung volume searched. CONCLUSION: Relationships between reader search, recognition and acceptance, and overall lung nodule detection rate can be studied with eye tracking. Radiologists appear to actively search less than half of the lung parenchyma, with substantial interreader variation in volume searched, fraction of nodules included within the search volume, sensitivity for nodules within the search volume, and overall detection rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Appropriate Reliance on Artificial Intelligence in Radiology Education
Li, M. D., & Little, B. P. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.04.019 · Cited by 52
Williams, L. H., & Drew, T. (2019) · Cognitive Research: Principles and Implications · doi:10.1186/s41235-019-0171-6 · Cited by 48
“Using a smaller UFOV (2.6° of visual angle), Rubin et al. (2015) found that average coverage for lung cancer screening was only 26.7%.”
BackgroundMethodInfluential
Metadata
- Authors
- Rubin, G. D., Roos, J. E., Tall, M., Harrawood, B., Bag, S., Ly, D. L., Seaman, D. M., Hurwitz, L. M., Napel, S., & Roy Choudhury, K.
- Venue
- Radiology
- Published
- 2015-01
- Volume
- 274
- Issue
- 1
- Pages
- 276-286
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1967003896
- Cited by
- 101
- References
- 0
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterizing Search, Recognition, and Decision in the Detection of Lung Nodules on CT Scans: Elucidation with Eye Tracking. https://app.cochat.ai/papers/10.1148/radiol.14132918
- The paper
- Rubin, G. D., Roos, J. E., Tall, M., Harrawood, B., Bag, S., Ly, D. L., Seaman, D. M., Hurwitz, L. M., Napel, S., & Roy Choudhury, K. (2015). Characterizing Search, Recognition, and Decision in the Detection of Lung Nodules on CT Scans: Elucidation with Eye Tracking. Radiology. https://doi.org/10.1148/radiol.14132918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.