Iodine Quantification to Distinguish Clear Cell from Papillary Renal Cell Carcinoma at Dual-Energy Multidetector CT: A Multireader Diagnostic Performance Study
Open accessAbstract
PURPOSE: To investigate whether dual-energy multidetector row computed tomographic (CT) imaging with iodine quantification is able to distinguish between clear cell and papillary renal cell carcinoma ( RCC renal cell carcinoma ) subtypes. MATERIALS AND METHODS: In this retrospective, HIPAA-compliant, institutional review board-approved study, 88 patients (57 men, 31 women) with diagnosis of either clear cell or papillary RCC renal cell carcinoma at pathologic analysis, who underwent contrast material-enhanced dual-energy nephrographic phase study between December 2007 and June 2013, were included. Five readers, blinded to pathologic diagnosis, independently evaluated all cases by determining the lesion iodine concentration on color-coded iodine maps. The receiving operating characteristic curve analysis was adopted to estimate the optimal threshold for discriminating between clear cell and papillary RCC renal cell carcinoma , and results were validated by using a leave-one-out cross-validation. Interobserver agreement was assessed by using an intraclass correlation coefficient. The correlation between tumor iodine concentration and tumor grade was investigated. RESULTS: A tumor iodine concentration of 0.9 mg/mL represented the optimal threshold to discriminate between clear cell and papillary RCC renal cell carcinoma , and it yielded the following: sensitivity, 98.2% (987 of 1005 [95% confidence interval: 97.7%, 98.7%]); specificity, 86.3% (272 of 315 [95% confidence interval: 85.0%, 87.7%]); positive predictive value, 95.8% (987 of 1030 [95% confidence interval: 95.0%, 96.6%]); negative predictive value, 93.7% (272 of 290 [95% confidence interval: 92.8%, 94.7%]); overall accuracy of 95.3% (1259 of 1320 [95% confidence interval: 94.6%, 96.2%]), with an area under the curve of 0.923 (95% confidence interval: 0.913, 0.933). An excellent agreement was found among the five readers in measured tumor iodine concentration (intraclass correlation coefficient, 0.9990 [95% confidence interval: 0. 9987, 0.9993). A significant correlation was found between tumor iodine concentration and tumor grade for both clear cell (τ = 0.85; P < .001) and papillary RCC renal cell carcinoma (τ = 0.53; P < .001). CONCLUSION: Dual-energy multidetector CT with iodine quantification can be used to distinguish between clear cell and papillary RCC renal cell carcinoma , and it provides insights regarding the tumor grade.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Cited by
Bosniak Classification of Cystic Renal Masses, Version 2019: An Update Proposal and Needs Assessment
Silverman, S. G., Pedrosa, I., Ellis, J. H., Hindman, N. M., Schieda, N., Smith, A. D., Remer, E. M., Shinagare, A. B., Curci, N. E., Raman, S. S., et al. (2019) · Radiology · doi:10.1148/radiol.2019182646 · Cited by 529
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Metadata
- Authors
- Mileto, A., Marin, D., Alfaro-Cordoba, M., Ramirez-Giraldo, J. C., Eusemann, C. D., Scribano, E., Blandino, A., Mazziotti, S., & Ascenti, G.
- Venue
- Radiology
- Published
- 2014-12
- Volume
- 273
- Issue
- 3
- Pages
- 813-820
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2001101119
- Cited by
- 174
- References
- 2
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iodine Quantification to Distinguish Clear Cell from Papillary Renal Cell Carcinoma at Dual-Energy Multidetector CT: A Multireader Diagnostic Performance Study. https://app.cochat.ai/papers/10.1148/radiol.14140171
- The paper
- Mileto, A., Marin, D., Alfaro-Cordoba, M., Ramirez-Giraldo, J. C., Eusemann, C. D., Scribano, E., Blandino, A., Mazziotti, S., & Ascenti, G. (2014). Iodine Quantification to Distinguish Clear Cell from Papillary Renal Cell Carcinoma at Dual-Energy Multidetector CT: A Multireader Diagnostic Performance Study. Radiology. https://doi.org/10.1148/radiol.14140171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.