The DOI matches its Crossref record.
Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography
Abstract
PURPOSE: To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons (ATs) by using real-time shear-wave elastography (SWE). MATERIALS AND METHODS: The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE studies of ATs without tendonopathy and 30 studies of the middle portion of the AT in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT tears at B-mode US and signal-void areas at SWE were noted. RESULTS: Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE. Tendon softening was a sign of tendonopathy in relaxed ATs when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE (sensitivity, 54.2%; 95% confidence interval [CI]: 32.8, 74.4; specificity, 91.5%; 95% CI: 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE (sensitivity, 41.7%; 95% CI: 22.1, 63.3; specificity, 81.8%; 95% CI: 75.3, 87.2) and in stretched ATs, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE (sensitivity, 66.7%; 95% CI: 44.7, 84.3; specificity, 75.6%; 95% CI: 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE (sensitivity, 58.3%; 95% CI: 36.7, 77.9; specificity, 83.5%; 95% CI: 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic ATs. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE. CONCLUSION: Whether the AT was relaxed or stretched, SWE helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE appeared to be highly specific, but sensitivity was relatively low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017) · RadioGraphics · doi:10.1148/rg.2017160116 · Cited by 729
Machine learning for medical ultrasound: status, methods, and future opportunities
Brattain, L. J., Telfer, B. A., Dhyani, M., Grajo, J. R., & Samir, A. E. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1517-0 · Cited by 262
Martin, R. L., Chimenti, R., Cuddeford, T., Houck, J., Matheson, J. W., McDonough, C. M., Paulseth, S., Wukich, D. K., & Carcia, C. R. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.0302 · Cited by 255
Metadata
- Authors
- Aubry, S., Nueffer, J.-P., Tanter, M., Becce, F., Vidal, C., & Michel, F.
- Venue
- Radiology
- Published
- 2015-03
- Volume
- 274
- Issue
- 3
- Pages
- 821-829
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2037396455
- Cited by
- 187
- References
- 0
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography. https://app.cochat.ai/papers/10.1148/radiol.14140434
- The paper
- Aubry, S., Nueffer, J.-P., Tanter, M., Becce, F., Vidal, C., & Michel, F. (2015). Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography. Radiology. https://doi.org/10.1148/radiol.14140434
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.