Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
Open accessAbstract
In the past 2 decades, sonoelastography has been progressively used as a tool to help evaluate soft-tissue elasticity and add to information obtained with conventional gray-scale and Doppler ultrasonographic techniques. Recently introduced on clinical scanners, shear-wave elastography (SWE) is considered to be more objective, quantitative, and reproducible than compression sonoelastography with increasing applications to the musculoskeletal system. SWE uses an acoustic radiation force pulse sequence to generate shear waves, which propagate perpendicular to the ultrasound beam, causing transient displacements. The distribution of shear-wave velocities at each pixel is directly related to the shear modulus, an absolute measure of the tissue’s elastic properties. Shear-wave images are automatically coregistered with standard B-mode images to provide quantitative color elastograms with anatomic specificity. Shear waves propagate faster through stiffer contracted tissue, as well as along the long axis of tendon and muscle. SWE has a promising role in determining the severity of disease and treatment follow-up of various musculoskeletal tissues including tendons, muscles, nerves, and ligaments. This article describes the basic ultrasound physics of SWE and its applications in the evaluation of various traumatic and pathologic conditions of the musculoskeletal system. ©RSNA, 2017
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan.
GOUTALLIER, D., Postel, J.-M., BERNAGEAU, J., Lavau, L., & Voisin, M. C. (1994) · PubMed · Cited by 2,554
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Classification of Rotator Cuff Lesions
Patte, D. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199005000-00012 · Cited by 872
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010) · Radiology · doi:10.1148/radiol.10090385 · Cited by 519
Quantitative Assessment of the Muscles of the Rotator Cuff with Magnetic Resonance Imaging
ZANETTI, M., GERBER, C., & HODLER, J. (1998) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199803000-00006 · Cited by 511
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
Ultrasound elastography for musculoskeletal applications
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2012) · The British Journal of Radiology · doi:10.1259/bjr/93042867 · Cited by 385
Eby, S. F., Cloud, B. A., Brandenburg, J. E., Giambini, H., Song, P., Chen, S., LeBrasseur, N. K., & An, K.-N. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.11.011 · Cited by 295
Cited by
Săftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Self-citationMachine learning for medical ultrasound: status, methods, and future opportunities
Brattain, L. J., Telfer, B. A., Dhyani, M., Grajo, J. R., & Samir, A. E. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1517-0 · Cited by 262
Frawley, H., Shelly, B., Morin, M., Bernard, S., Bø, K., Digesu, G. A., Dickinson, T., Goonewardene, S., McClurg, D., Rahnama'i, M. S., et al. (2021) · Neurourology and Urodynamics · doi:10.1002/nau.24658 · Cited by 246
Evaluation of effects of aging on skeletal muscle elasticity using shear wave elastography
Şendur, H. N., Cindil, E., Cerit, M. N., Kılıç, P., Gültekin, I. İ., & Oktar, S. Ö. (2020) · European Journal of Radiology · doi:10.1016/j.ejrad.2020.109038 · Cited by 60
Skeletal Muscle Assessment Using Quantitative Ultrasound: A Narrative Review
Ashir, A., Jerban, S., Barrère, V., Wu, Y., Shah, S. B., Andre, M. P., & Chang, E. Y. (2023) · Sensors · doi:10.3390/s23104763 · Cited by 57
Metadata
- Authors
- Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S.
- Venue
- RadioGraphics
- Published
- 2017-05
- Volume
- 37
- Issue
- 3
- Pages
- 855-870
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2613669501
- Cited by
- 729
- References
- 37
- FWCI
- 20.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications. https://app.cochat.ai/papers/10.1148/rg.2017160116
- The paper
- Taljanovic, M. S., Gimber, L. H., Becker, G. W., Latt, L. D., Klauser, A. S., Melville, D. M., Gao, L., & Witte, R. S. (2017). Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications. RadioGraphics. https://doi.org/10.1148/rg.2017160116
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.