The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis
Abstract
PURPOSE: To prospectively compare the technical success rate and accuracy of shear-wave elastography (SWE) and transient elastography (TE) for the detection of clinically significant portal hypertension (PH) in patients with advanced cirrhosis who are undergoing hepatic vein pressure gradient (HVPG) measurements. MATERIALS AND METHODS: The institutional ethics committee approved the study, and written informed consent was obtained. Seventy-nine consecutive patients with cirrhosis who were undergoing SWE and TE at the time of HVPG measurement were studied. The technical success rate of SWE and TE was compared with the diagnostic value of liver stiffness (LS) and spleen stiffness (SS) measurements and composite scores (LS spleen-diameter-to-platelet-ratio score [LSPS] and PH risk score) by using SWE and TE to detect clinically significant PH (HVPG ≥ 10 mm Hg) and esophageal varices at high risk of bleeding. Areas under the receiver operating characteristic curve and the DeLong test were used. RESULTS: The technical success rate of SWE was significantly better than that of TE for both LS and SS (97% and 97% vs 44% and 42%, respectively; P < .001). LS of more than 24.6 kPa with SWE had a sensitivity, specificity, and accuracy for clinically significant PH of 81%, 88%, and 82%, respectively. Diagnostic performance of LS by using SWE was significantly better than that for SS for the diagnosis of clinically significant PH (area under the receiver operating characteristic curve of 0.87 vs 0.64, P = .003). LS, SS, LSPS, and PH risk score (according to SWE or TE) did not differ between patients with and those without high-risk esophageal varices (P = .09-.42). CONCLUSION: In patients with advanced cirrhosis who are undergoing HVPG measurements, LS measurements obtained by using SWE have a higher technical success rate and a better diagnostic value than TE for clinically significant PH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Cited by
Garcia‐Tsao, G., Abraldes, J. G., Berzigotti, A., & Bosch, J. (2017) · Hepatology · doi:10.1002/hep.28906 · Cited by 2,154
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Dietrich, C., Bamber, J., Berzigotti, A., Bota, S., Cantisani, V., Castera, L., Cosgrove, D., Ferraioli, G., Friedrich-Rust, M., Gilja, O., et al. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0043-103952 · Cited by 1,011
Ferraioli, G., Wong, V. W.-S., Castera, L., Berzigotti, A., Sporea, I., Dietrich, C. F., Choi, B. I., Wilson, S. R., Kudo, M., & Barr, R. G. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.07.008 · Cited by 574
Metadata
- Authors
- Elkrief, L., Rautou, P.-E., Ronot, M., Lambert, S., Dioguardi Burgio, M., Francoz, C., Plessier, A., Durand, F., Valla, D., Lebrec, D., Vilgrain, V., & Castéra, L.
- Venue
- Radiology
- Published
- 2015-05
- Volume
- 275
- Issue
- 2
- Pages
- 589-598
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2158584608
- Cited by
- 236
- References
- 1
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis. https://app.cochat.ai/papers/10.1148/radiol.14141210
- The paper
- Elkrief, L., Rautou, P.-E., Ronot, M., Lambert, S., Dioguardi Burgio, M., Francoz, C., Plessier, A., Durand, F., Valla, D., Lebrec, D., Vilgrain, V., & Castéra, L. (2015). Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis. Radiology. https://doi.org/10.1148/radiol.14141210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).