Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis

Elkrief, Laure, Rautou, Pierre-Emmanuel, Ronot, Maxime, Lambert, Simon, Dioguardi Burgio, Marco, Francoz, Claire, Plessier, Aurélie, Durand, François, Valla, Dominique, Lebrec, Didier, Vilgrain, Valérie, Castéra, Laurent·2015·Radiology

Abstract

PURPOSE: To prospectively compare the technical success rate and accuracy of shear-wave elastography (SWE) and transient elastography (TE) for the detection of clinically significant portal hypertension (PH) in patients with advanced cirrhosis who are undergoing hepatic vein pressure gradient (HVPG) measurements. MATERIALS AND METHODS: The institutional ethics committee approved the study, and written informed consent was obtained. Seventy-nine consecutive patients with cirrhosis who were undergoing SWE and TE at the time of HVPG measurement were studied. The technical success rate of SWE and TE was compared with the diagnostic value of liver stiffness (LS) and spleen stiffness (SS) measurements and composite scores (LS spleen-diameter-to-platelet-ratio score [LSPS] and PH risk score) by using SWE and TE to detect clinically significant PH (HVPG ≥ 10 mm Hg) and esophageal varices at high risk of bleeding. Areas under the receiver operating characteristic curve and the DeLong test were used. RESULTS: The technical success rate of SWE was significantly better than that of TE for both LS and SS (97% and 97% vs 44% and 42%, respectively; P < .001). LS of more than 24.6 kPa with SWE had a sensitivity, specificity, and accuracy for clinically significant PH of 81%, 88%, and 82%, respectively. Diagnostic performance of LS by using SWE was significantly better than that for SS for the diagnosis of clinically significant PH (area under the receiver operating characteristic curve of 0.87 vs 0.64, P = .003). LS, SS, LSPS, and PH risk score (according to SWE or TE) did not differ between patients with and those without high-risk esophageal varices (P = .09-.42). CONCLUSION: In patients with advanced cirrhosis who are undergoing HVPG measurements, LS measurements obtained by using SWE have a higher technical success rate and a better diagnostic value than TE for clinically significant PH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.14141210

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Elkrief, L., Rautou, P.-E., Ronot, M., Lambert, S., Dioguardi Burgio, M., Francoz, C., Plessier, A., Durand, F., Valla, D., Lebrec, D., Vilgrain, V., & Castéra, L.
Venue
Radiology
Published
2015-05
Volume
275
Issue
2
Pages
589-598
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2158584608
Cited by
236
References
1
FWCI
10.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis. https://app.cochat.ai/papers/10.1148/radiol.14141210
The paper
Elkrief, L., Rautou, P.-E., Ronot, M., Lambert, S., Dioguardi Burgio, M., Francoz, C., Plessier, A., Durand, F., Valla, D., Lebrec, D., Vilgrain, V., & Castéra, L. (2015). Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis. Radiology. https://doi.org/10.1148/radiol.14141210

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.