The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Gadolinium-based Contrast Agent Accumulates in the Brain Even in Subjects without Severe Renal Dysfunction: Evaluation of Autopsy Brain Specimens with Inductively Coupled Plasma Mass Spectroscopy
Abstract
PURPOSE: To use inductively coupled plasma mass spectroscopy (ICP-MS) to evaluate gadolinium accumulation in brain tissues, including the dentate nucleus (DN) and globus pallidus (GP), in subjects who received a gadolinium-based contrast agent (GBCA). MATERIALS AND METHODS: Institutional review board approval was obtained for this study. Written informed consent for postmortem investigation was obtained either from the subject prior to his or her death or afterward from the subject's relatives. Brain tissues obtained at autopsy in five subjects who received a linear GBCA (GBCA group) and five subjects with no history of GBCA administration (non-GBCA group) were examined with ICP-MS. Formalin-fixed DN tissue, the inner segment of the GP, cerebellar white matter, the frontal lobe cortex, and frontal lobe white matter were obtained, and their gadolinium concentrations were measured. None of the subjects had received a diagnosis of severely compromised renal function (estimated glomerular filtration rate <45 mL/min/1.73 m(2)) or acute renal failure. Fisher permutation test was used to compare gadolinium concentrations between the two groups and among brain regions. RESULTS: Gadolinium was detected in all specimens in the GBCA agent group (mean, 0.25 µg per gram of brain tissue ± 0.44 [standard deviation]), with significantly higher concentrations in each region (P = .004 vs the non-GBCA group for all regions). In the GBCA group, the DN and GP showed significantly higher gadolinium concentrations (mean, 0.44 µg/g ± 0.63) than other regions (0.12 µg/g ± 0.16) (P = .029). CONCLUSION: Even in subjects without severe renal dysfunction, GBCA administration causes gadolinium accumulation in the brain, especially in the DN and GP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Self-citationBiodistribution of gadolinium‐based contrast agents, including gadolinium deposition
Aime, S., & Caravan, P. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21969 · Cited by 534
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
White, G. W., Gibby, W. A., & Tweedle, M. F. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000186569.32408.95 · Cited by 362
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
Incorporation of excess gadolinium into human bone from medical contrast agents
Darrah, T. H., Prutsman-Pfeiffer, J. J., Poreda, R. J., Ellen Campbell, M., Hauschka, P. V., & Hannigan, R. E. (2009) · Metallomics · doi:10.1039/b905145g · Cited by 299
Sieber, M. A., Pietsch, H., Walter, J., Haider, W., Frenzel, T., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e31815e6277 · Cited by 207
Sieber, M. A., Lengsfeld, P., Frenzel, T., Golfier, S., Schmitt-Willich, H., Siegmund, F., Walter, J., Weinmann, H.-J., & Pietsch, H. (2008) · European Radiology · doi:10.1007/s00330-008-0977-y · Cited by 203
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Gadolinium deposition in the brain: summary of evidence and recommendations
Gulani, V., Calamante, F., Shellock, F. G., Kanal, E., & Reeder, S. B. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30158-8 · Cited by 784
Gadolinium-based contrast agent toxicity: a review of known and proposed mechanisms
Rogosnitzky, M., & Branch, S. (2016) · BioMetals · doi:10.1007/s10534-016-9931-7 · Cited by 766
Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update
Ramalho, J., Semelka, R. C., Ramalho, M., Nunes, R. H., AlObaidy, M., & Castillo, M. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4615 · Cited by 453
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Metadata
- Authors
- Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S.
- Venue
- Radiology
- Published
- 2015-07
- Volume
- 276
- Issue
- 1
- Pages
- 228-232
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2155961553
- Cited by
- 874
- References
- 8
- FWCI
- 46.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.